Factors affecting the cement penetration of a hip resurfacing implant: an in vitro study.

نویسندگان

  • R Howald
  • U Kesteris
  • R Klabunde
  • J Krevolin
چکیده

An understanding of how the cementing technique influences cement penetration is important for surgeons to plan and conduct hip resurfacing procedures. Therefore the aim of this study is to determine the influence of the following parameters on cement penetration: use of pulse lavage, type of cement, and the standing period of the cement. Nine fresh frozen paired whole cadaver femora were used to investigate cement penetration. The femora were divided into three paired groups: (A) compared the use of pulse lavage to no pulse lavage, (B) compared two low viscosity bone cements SULCEM-3 (Zimmer GmbH, Switzerland) and Surgical Simplex (Stryker Orthopaedics, USA), and (C) compared bone cement viscosities using standing times of 1.5 min. and 3 min. The Durom Hip Resurfacing implant (Zimmer GmbH, Switzerland) was used in all groups. A single slice was taken out of the center of each head. Cement penetration ratio (penetration area divided by the bone area enclosed by implant) and mean cement penetration depth were measured. Cement penetration is increased using pulse lavage, and has the tendency to increase with increasing the cement standing time from 1.5 to 3 min. No difference in cement penetration was found when different cement brands of comparable viscosity were used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cement Penetration into Femoral Head with Longitudinal Slot Following Hip Resurfacing Arthroplasty

+Snyder, S; Jamali, A A; Hazelwood, S J +California Polytechnic State University, San Luis Obispo, CA, University of California Davis Medical Center, Sacramento, CA [email protected] INTRODUCTION Hip resurfacing arthroplasty is seen as advantageous in younger, active patients due to its preservation of bone. Failure of these implants, though, can be very traumatic and potentially life threat...

متن کامل

Cementing techniques in hip resurfacing.

The subject of the cementing technique in hip resurfacing has been poorly studied to date. The hip resurfacing prosthesis is unique in the family of cemented prostheses because the cement mantle is blind (hidden underneath the implant) and is radiographically obscured. This presents an immediate challenge to the surgeon at the time of surgery, but also has a longer-term implication in terms of ...

متن کامل

Efficacy of hip resurfacing arthroplasty: 6 year results from an international multisurgeon prospective cohort study.

Metal-on-metal hip resurfacing is undertaken worldwide. This procedure helps preserve femoral bone stock and allows patients to return to high activity sports. Most outcome studies are individual surgeon case series from single centers where the results and outcomes are evaluated by the same surgeon. One method of increasing the external validity of a follow-up study is to have a multi-centre s...

متن کامل

Comparative Evaluation of Microleakage at the Interface of Titanium and Zirconium Abutments Following Oblique Cyclic Loading: An in vitro Study

Abstract Background and aim: Oral microbiota could proliferate the microspace between the implant and abutment, thereby cause inflammation in the peri-implant tissues and adjacent bone. This study aimed to investigate the effect of two types of abutments (zirconia and titanium) on microleakage at implant-abutment interface area under oblique cyclic loading in vitro. Materials and methods:In thi...

متن کامل

The influence of the size of the component on the outcome of resurfacing arthroplasty of the hip: a review of the literature.

The survivorship of contemporary resurfacing arthroplasty of the hip using metal-on-metal bearings is better than that of first generation designs, but short-term failures still occur. The most common reasons for failure are fracture of the femoral neck, loosening of the component, osteonecrosis of the femoral head, reaction to metal debris and malpositioning of the component. In 2008 the Austr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hip international : the journal of clinical and experimental research on hip pathology and therapy

دوره 16 Suppl 4  شماره 

صفحات  -

تاریخ انتشار 2006