Scientific basis for standardization of fetal head measurements by ultrasound: a reproducibility study
نویسندگان
چکیده
OBJECTIVE To compare the standard methods for ultrasound measurement of fetal head circumference (HC) and biparietal diameter (BPD) (outer-to-outer (BPDoo) vs outer-to-inner (BPDoi) caliper placement), and compare acquisition of these measurements in transthalamic (TT) vs transventricular (TV) planes. METHODS This study utilized ultrasound images acquired from women participating in the Oxford arm of the INTERGROWTH-21(st) Project. In the first phase of the study, BPDoo and BPDoi were measured on stored images. In the second phase, real-time measurements of BPD, occipitofrontal diameter (OFD) and HC in TT and TV planes were obtained by pairs of sonographers. Reproducibility of measurements made by the same (intraobserver) and by different (interobserver) sonographers, as well as the reproducibility of caliper placement and measurements obtained in different planes, was assessed using Bland-Altman plots. RESULTS In Phase I, we analyzed ultrasound images of 108 singleton fetuses. The mean intraobserver and interobserver differences were < 2% (1.34 mm) and the 95% limits of agreement were < 5% (3 mm) for both BPDoo and BPDoi. Neither method for measuring BPD showed consistently better reproducibility. In Phase II, we analyzed ultrasound images of 100 different singleton fetuses. The mean intraobserver and interobserver differences were < 1% (2.26 mm) and the 95% limits of agreement were < 8% (14.45 mm) for all fetal head measurements obtained in TV and TT planes. Neither plane for measuring fetal head showed consistently better reproducibility. Measurement of HC using the ellipse facility was as reproducible as HC calculated from BPD and OFD. OFD by itself was the least reproducible of all fetal head measurements. CONCLUSIONS Measurements of BPDoi and BPDoo are equally reproducible; however, we believe BPDoo should be used in clinical practice as it allows fetal HC to be measured and compared with neonatal HC. For all head measurements, TV and TT planes provide equally reproducible values at any gestational age, and HC values are similar in both planes. Fetal head measurement in the TT plane is preferable as international standards in this plane are available; however, measurements in the TV plane can be plotted on the same standards. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.
منابع مشابه
Circumference measurements in obstetrical ultrasound: ellipse vs. arithmetic mean.
Quantitation of fetal parameters by prenatal sonography enables the assessment of menstrual age and fetal development. Appropriate fetal growth can be surmised on the basis of sequential measurements, as well as the relative variation of parameters such as biparietal diameter (BPD), femur diaphysis length (FDL), abdominal circumference (AC 1, and head circumference (HC). Accurate determination ...
متن کاملStandardization of fetal ultrasound biometry measurements: improving the quality and consistency of measurements.
OBJECTIVE To assess whether a standardization exercise prior to commencing a fetal growth study involving multiple sonographers can reduce interobserver variation. METHODS In preparation for an international study assessing fetal growth, nine experienced sonographers from eight countries participated in a standardization exercise consisting of theoretical and practical sessions. Each performe...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کاملFetal Cerebellar Vermis Circumference Measured by 2-Dimensional Ultrasound Scan: Reference Range, Feasibility and Reproducibility.
Purpose: To provide 2-dimensional ultrasonographic (2D-US) normograms of cerebellar vermis biometry, as well as to evaluate the feasibility and the reproducibility of these measurements in clinical practice. Materials and Methods: A prospective cross-sectional study of 328 normal singleton pregnancies between 18 and 33 weeks of gestation. Measurements of the fetal cerebellar vermis circumferenc...
متن کاملRE: Ultrasonic Measurement of Testicular Tumors and the Correlation with Pathologic Specimen Sizes
We read with great interest the article “The value of testicular ultrasound in the prediction of the type and size of testicular tumors” by Shtricker et al. (1). They aimed to assess the correlation between ultrasound (US) findings and testicular tumor type and size. The authors concluded that the testis US findings underestimated the size in 25% of the malignant testicular lesions and 16% of t...