One possible loosening mechanism of the femoral component in total hip replacement is fatigue cracking of the cement mantle. A computational method capable of simulating this process may therefore be a useful tool in the preclinical evaluation of prospective implants. In this study, we investigated the ability of a computational method to predict fatigue cracking in experimental models of the implanted femur construct. Experimental specimens were fabricated such that cement mantle visualisation was possible throughout the test. Two different implant surface finishes were considered: grit blasted and polished. Loading was applied to represent level gait for two million cycles. Computational (finite element) models were generated to the same geometry as the experimental specimens, with residual stress and porosity simulated in the cement mantle. Cement fatigue and creep were modelled over a simulated two million cycles. For the polished stem surface finish, the predicted fracture locations in the finite element models closely matched those on the experimental specimens, and the recorded stem displacements were also comparable. For the grit blasted stem surface finish, no cement mantle fractures were predicted by the computational method, which was again in agreement with the experimental results. It was concluded that the computational method was capable of predicting cement mantle fracture and subsequent stem displacement for the structure considered.
منابع مشابه
Mesh Considerations for Adaptive Finite Element Analyses of Cement Failure in Total Hip Replacement
INTRODUCTION Failure of the cement mantle has been identified as a possible mode of failure of the implanted femur in total hip replacement (THR) [1]. Finite element (FE) analyses have been used to investigate the stresses experienced in the cement mantle [2] and to predict the life of the cement mantle when taking different factors into account [3]. The number of elements used, or mesh density...
متن کاملIn vitro fatigue failure of cemented acetabular replacements: a hip simulator study.
Although hip simulators for in vitro wear testing of prosthetic materials used in total hip arthroplasty (THA) have been available for a number of years, similar equipment has yet to appear for endurance testing of fixation in cemented THA, despite considerable evidence of late aseptic loosening as one of the most significant failure mechanisms in this type of replacements. An in vitro study of...
متن کاملWhy would cement porosity reduction be clinically irrelevant, while experimental data show the contrary.
Laboratory bench tests have shown that porosity reduction increases the fatigue life of bone cement specimens. Clinically, however, the effect porosity reduction is subject to debate. We hypothesized that the discrepancy between clinical and experimental findings is related to differences in the stress distribution, which is typically uniform in experimental test specimens, while stress concent...
متن کاملAnalysis of Cement Mantle in Relation to Surgical Approach
Aseptic loosening remains the commonest cause of failure of total hip arthroplasty. Cement mantle defects are associated with aseptic loosening. Cementing technique has a profound influence on the incidence of aseptic loosening of total hip replacements. Two specific measures that seem to have the greatest impact on the longevity of cemented femoral stems are pressurization of cement and contro...
متن کاملA new fibre reinforced bone model to pre-clinical test for cement fatigue in total hip replacement
Introduction: The aseptic loosening of cemented hip prostheses, resulting from a combination of mechanical and biological factors, has emerged as one of the major concerns in total hip replacement. In order to investigate the contributing mechanical factors (e.g. cement fatigue, interface mechanics, surface finish) and the long-term effects, pre-clinical test models that are able to reproduce t...