Intraoperative 2D and 3D transoesophageal echocardiographic predictors of aortic regurgitation after transcatheter aortic valve implantation.

نویسندگان

  • Paola Gripari
  • See Hooi Ewe
  • Laura Fusini
  • Manuela Muratori
  • Arnold C T Ng
  • Claudia Cefalù
  • Victoria Delgado
  • Martin J Schalij
  • Jeroen J Bax
  • Nina Ajmone Marsan
  • Gloria Tamborini
  • Mauro Pepi
چکیده

BACKGROUND Post-procedural aortic regurgitation (AR) has been described in a large number of patients receiving transcatheter aortic valve implantation (TAVI). OBJECTIVE The aim of this study was to examine the intraoperative 2-dimensional (2D) and 3-dimensional (3D) echocardiographic features of the aortic valve associated with significant post-procedural paravalvular AR. METHODS A total of 135 patients (81±7 years) with severe symptomatic aortic stenosis, who underwent TAVI, were imaged with comprehensive 2D and 3D transoesophageal echocardiography before the procedure and peri-procedure. Various baseline and peri-procedural echocardiographic characteristics were tested to predict paravalvular AR post-TAVI: calcifications at the aortic valve commissures and leaflets, 'aortic annulus eccentricity index', 'area cover index', overlap between aortic prosthesis and anterior mitral leaflet. Post-procedural paravalvular AR≥2 was considered significant. RESULTS Successful TAVI was achieved in all patients. The incidence of paravalvular AR≥2 immediately after the procedure was 21% (28 patients). Commissural calcifications and, particularly, the calcification of the commissure between the right coronary and non-coronary cusps was significantly more frequent in presence of paravalvular AR; the area cover index pre-TAVI was significantly lower among patients with AR (11.1±11.8% vs 20.8±12.5%, p=0.0004). Multivariate analysis revealed that calcification of the commissure between the right coronary and non-coronary cusps (OR=2.66, 95% CI 1.39 to 5.12, p=0.001), and the area cover index pre-TAVI (OR=0.95, 95% CI 0.91 to 0.99, p=0.006) were the only independent predictors of significant paravalvular AR after TAVI. CONCLUSIONS Intraoperative 2D and 3D transoesophageal echocardiography identified calcification of the commissure between the right coronary and non-coronary cusps and the area cover index as independent predictors of significant paravalvular AR following TAVI.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter aortic valve implantation of a second-generation valve for pure aortic regurgitation: procedural outcome, haemodynamic data and follow-up.

OBJECTIVES The second-generation Jenavalve prosthesis (Jenavalve Technology, Inc., Munich, Germany) is the first transcatheter valve Conformité Européene (CE) marked for treatment of both aortic stenosis (AS) and pure aortic regurgitation (AR). Although the feasibility of the Jenavalve transcatheter aortic valve implantation (TAVI) in patients with pure AR has been described, haemodynamic and f...

متن کامل

"Balloon withdrawal technique" to correct prosthesis malposition and treat paravalvular aortic regurgitation during TAVI.

Transcatheter aortic valve implantation (TAVI) is an emerging technology used to treat high-risk patients with severe aortic stenosis. During TAVI with the CoreValve ReValving System, a balloon is used for the reduction of paravalvular regurgitation. However, in this paper, we describe the "balloon withdrawal" technique through which the positioning of a second valve can be avoided in case of i...

متن کامل

Evaluation and management of paravalvular aortic regurgitation after transcatheter aortic valve replacement.

Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame ...

متن کامل

Quantitative analysis of paravalvular leak of transcatheter aortic valves using cardiac MR

Background There is now extensive registry and clinical trial data demonstrating an increased incidence of paravalvular leak following transcatheter aortic valve implantation (TAVI) when compared with open aortic valve replacement (AVR). Despite recent improvements in both hardware and software, echocardiographic measurement of aortic regurgitation (AR) largely remains qualitative in nature. Ca...

متن کامل

Cardiac Function and Aortic Valve Intervention - Echocardiographic Studies of Myocardial Recovery in Patients with Severe Aortic Valve Disease

....................................................................................................... 1 POPULÄRVETENSKAPLIG SAMMANFATTNING ................................. 3 LIST OF ORIGINAL PAPERS ........................................................................ 5 ABBREVIATIONS ............................................................................................. 6 INTRODUCTIO...