3D Parylene sheath neural probe for chronic recordings.

نویسندگان

  • B J Kim
  • J T W Kuo
  • S A Hara
  • C D Lee
  • L Yu
  • C A Gutierrez
  • T Q Hoang
  • V Pikov
  • E Meng
چکیده

OBJECTIVE Reliable chronic recordings from implanted neural probes remain a significant challenge; current silicon-based and microwire technologies experience a wide range of biotic and abiotic failure modes contributing to loss of signal quality. APPROACH A multi-prong alternative strategy with potential to overcome these hurdles is introduced that combines a novel three dimensional (3D), polymer-based probe structure with coatings. Specifically, the Parylene C sheath-based neural probe is coated with neurotrophic and anti-inflammatory factors loaded onto a Matrigel carrier to encourage the ingrowth of neuronal processes for improved recording quality, reduce the immune response, and promote improved probe integration into brain tissue for reliable, long-term implementation compared to its rigid counterparts. MAIN RESULTS The 3D sheath structure of the probe was formed by thermal molding of a surface micromachined Parylene C microchannel, with electrode sites lining the interior and exterior regions of the lumen. Electrochemical characterization of the probes via cyclic voltammetry and electrochemical impedance spectroscopy was performed and indicated suitable electrode properties for neural recordings (1 kHz electrical impedance of ∼200 kΩ in vitro). A novel introducer tool for the insertion of the compliant polymer probe into neural tissue was developed and validated both in vitro using agarose gel and in vivo in the rat cerebral cortex. In vivo electrical functionality of the Parylene C-based 3D probes and their suitability for recording the neuronal activity over a 28-day period was demonstrated by maintaining the 1 kHz electrical impedance within a functional range (<400 kΩ) and achieving a reasonably high signal-to-noise ratio for detection of resolvable multi-unit neuronal activity on most recording sites in the probe. Immunohistochemical analysis of the implant site indicated strong correlations between the quality of recorded activity and the neuronal/astrocytic density around the probe. SIGNIFICANCE The provided electrophysiological and immunohistochemical data provide strong support to the viability of the developed probe technology. Furthermore, the obtained data provide insights into further optimization of the probe design, including tip geometry, use of neurotrophic and anti-inflammatory drugs in the Matrigel coating, and placement of the recording sites.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration.

A Parylene C neural probe with a three dimensional sheath structure was designed, fabricated, and characterized. Multiple platinum (Pt) electrodes for recording neural signals were fabricated on both inner and outer surfaces of the sheath structure. Thermoforming of Parylene was used to create the three dimensional sheath structures from flat surface micromachined microchannels using solid micr...

متن کامل

Arrayed 3d Parylene Sheath Probes for Neural Recordings

Parylene C arrayed neural probes possessing 3D sheath structures that can be decorated with neurotrophic factors for attracting and promoting neural tissue ingrowth are presented for long-term intracortical neural recording. 3D sheath structures were constructed through thermoforming of surface micromachined Parylene microchannels around a solid microwire mold. Multiple Pt electrodes were patte...

متن کامل

Fabrication of 3d Parylene Sheath Probes for Reliable Neuroprosthetic Recordings

3D Parylene sheath probes having Pt electrodes on the outer and inner surfaces of the sheath are introduced as a novel interface for long term intracortical neural recording. Surface micromachined Parylene channels with Pt electrodes are expanded into a 3D sheath structure by thermoforming in the presence of a custom tapered microwire that shapes the sheath. Electrochemical characterization, in...

متن کامل

Electrochemical Characterization of a 3d Parylene Sheath Cortical Probe

We developed a 3D Parylene sheath cortical probe for the purpose of advancing neuronal recording reliability and longevity. Our approach is to improve probe-tissue integration through a unique 3D open-lumen probe structure and the application of biofunctional coatings to mitigate adverse immune reactions and promote neuronal growth. We present the use of electrochemical (EC) testing to confirm ...

متن کامل

A Novel Flexible Sinusoidal Probe for Chronic Extracellular Brain Recording

Current microelectrodes designed to record chronic neural activity suffer from recording instabilities due to the modulus mismatch between the electrode materials and the brain. We sought to address this by microfabricating a novel flexible neural probe. Our probe was fabricated from parylene-C with a WTi metal, using contact photolithography and reactive ion etching, with three design features...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neural engineering

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2013