The effect of variation in slice thickness and interslice gap on MR lesion detection.
نویسندگان
چکیده
Lesion detection by MR imaging depends on the contrast-to-noise ratio of the voxels containing the lesion relative to those containing the background. When the lesion voxels are less than completely filled, the inherent contrast between lesion and background is modified by the filling factor. Lesion detection thus depends on lesion size, slice thickness, lesion position relative to slice, thickness of gap between slices, and inherent contrast between lesion and background. Using computer simulation, the effect of variation in the slice thickness and the interslice gap on lesion detection is modeled as a function of lesion size, filling factor, and inherent contrast. Detection of small, low-contrast lesions is shown to be most sensitive to partial volume effects and to be greatest with thin slices. Detection of high-contrast lesions is shown to be limited primarily by the presence of a gap between slices. For patients with diffusely distributed disease-e.g., the small, low-contrast lesions of multiple sclerosis-lesion detection is greater for thin slices, even with a gap, than for thick, contiguous slices.
منابع مشابه
Optimization of Brain T2 Mapping using Standard CPMG Sequence in a Clinical Scanner
In magnetic resonance imaging, transverse relaxation time (T2) mapping is a useful quantitative tool enabling enhanced diagnostics of many brain pathologies. The aim of our study was to test the influence of different sequence parameters on calculated T2 values, including multi-slice measurements, slice position, interslice gap, echo spacing, and pulse duration. Measurements were performed usin...
متن کاملMR imaging of orbital and ocular disease.
Magnetic resonance (MR) images of 27 patients with ocular and orbital pathology were reviewed retrospectively and correlated with computed tomography (CT), funduscopic examination, and tissue histology. Disease processes were classified by location into ocular, extraconal, intraconal, optic nerve, and orbital apex. The diagnostic efficacy of MR differed at each location. MR was very sensitive i...
متن کاملInvestigation of the effect of slice thickness and Kvp changes on the accuracy of linear measurements in CBCT: In vitro study
Background and Aim: The accuracy of linear measurements in CBCT images is one of the critical parameters in treatment planning. Slice thickness and exposure parameters seem to affect the accuracy of linear measurements. In this study, we investigated the impact of the above factors on the accuracy of linear measurements in CBCT. Materials and Methods: For the in vitro experiment, three dry huma...
متن کاملOptimal Design of Magnetorheological Fluid Damper Based on Response Surface Method
In this research, the effect of shape parameters such as number of magnet wire turns, spools, thickness of the gap, and pole length in a Magneto-rheological (MR) fluid damper is analytically investigated and the optimization of these parameters is done with response surface method (RSM) which is combined Neuro-Fuzzy method and Particle Swarm Optimization (PSO) algorithm. Since the electro-magne...
متن کاملEffect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro
Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 8 6 شماره
صفحات -
تاریخ انتشار 1987