An Automated 96-Well-Plate Loader for the FACScan

نویسنده

  • Harald Illges
چکیده

Staining multiple samples for data acquisition with a flow cytometer is done in 96-well plates to save time and make large data assessment in one working day possible. However, the inability of the FACScan R © to take up the samples from 96well plates is a major drawback. In order to avoid the individual transfer of samples to tubes, we have developed a system, which allows using the FACScan R © with 96-well plates. The machine consists of a programmable control module and a loader which moves the 96-well plate in 3 axis well by well along the sample collector. The machine is equipped with a wash buffer tank to avoid cross contamination of samples and a shaking option to avoid sedimentation of cells during acquisition. The machine can be further developed into a full automatic loader if connected to the FACS Station. In 24 hours about 7,000 samples with 10,000 cells each can be acquired.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated, quantitative cytopathic effect reduction assay for interferon.

A rapid, cytopathic effect reduction assay for human interferon (IFN) is described. Dilutions of IFN were made with an automated diluter in 96-well microtiter plates. Total incubation time was 26 h. IFN titers were calculated from optical density readings of crystal violet-stained monolayers in an automated spectrophotometer, which required less than 1 min to read each plate.

متن کامل

Dynamics of Industrial Buyer Behavior of Loader Backhoe

To investigate how the buying behavior of firms work is always needed, since it is an every changing process influenced by many forces in its surroundings. Industrial firms tend to have a smaller number of customers which means that they are easier to identify than customers in consumer markets. Effective marketing strategy relies on understanding consumers and their needs. This understanding m...

متن کامل

Improved method for fluorescence cytometric immunohematology testing.

BACKGROUND A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. STUDY DESIGN AND METHODS A modified procedure was developed that used low-speed centrifugation of 96-...

متن کامل

PN 33354 - IMAC Purification of Polyhistidine-tagged Protein Using the AcroPrepTM 96 Filter Plate

Bottlenecks in protein sample preparation highlight the need to optimize screening strategies and develop more effective automated systems to recover proteins for proteomic analysis. Fully automated purification strategies may include a number of steps where lysate clearance (AcroPrep 96 prefiltration plates), desalting and protein concentration (AcroPrep 96 ultrafiltration plates) are needed. ...

متن کامل

A New Method to Improve Automated Classification of Heart Sound Signals: Filter Bank Learning in Convolutional Neural Networks

Introduction: Recent studies have acknowledged the potential of convolutional neural networks (CNNs) in distinguishing healthy and morbid samples by using heart sound analyses. Unfortunately the performance of CNNs is highly dependent on the filtering procedure which is applied to signal in their convolutional layer. The present study aimed to address this problem by a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 1999