Tibiofemoral contact mechanics with a femoral resurfacing prosthesis and a non-functional meniscus.
نویسندگان
چکیده
BACKGROUND Increased contact stress with a femoral resurfacing prosthesis implanted in the medial femoral condyle and a non-functional meniscus is of concern for potential deleterious effects on tibiofemoral contact mechanics. METHODS Peak contact pressures were determined in seven fresh frozen human cadaveric specimens using a pressure sensitive sensor placed in the medial compartment above the menisci. A knee simulator was used to test each knee in static stance positions (5 degrees/15 degrees/30 degrees/45 degrees) and through 10 dynamic knee flexion cycles (5-45 degrees) with single body weight ground reaction force which was adjusted to the living body weight of the cadaver donor. All specimens were tested in three different conditions: untreated knee (A); flush implantation of a 20mm resurfacing prosthesis (HemiCAP) in the weight bearing area of the medial femoral condyle (B); complete radial tear at the posterior horn of the medial meniscus with the femoral resurfacing device in place (C). FINDINGS On average, flush device implantation resulted in no statistically significant differences when compared to the untreated normal knee. The meniscal tear resulted in a significant increase of the mean maximum peak contact pressures by 63%, 57%, and 57% (all P< or =0.05) at 15 degrees , 30 degrees and 45 degrees static stance positions and 78% (P< or =0.05) through the dynamic knee flexion cycle. No significant different maximum peak contact pressures were observed at 5 degrees stance position. INTERPRETATION Although the condition of a meniscal tear without the resurfacing device could not be compared, possible effects of reduced meniscal tissue and biomechanical integrity of the meniscus must be considered in an in vivo application.
منابع مشابه
In-vivo evaluation of the kinematic behavior of an artificial medial meniscus implant: A pilot study using open-MRI.
BACKGROUND In this pilot study we wanted to evaluate the kinematics of a knee implanted with an artificial polycarbonate-urethane meniscus device, designed for medial meniscus replacement. The static kinematic behavior of the implant was compared to the natural medial meniscus of the non-operated knee. A second goal was to evaluate the motion pattern, the radial displacement and the deformation...
متن کاملTibiofemoral contact mechanics following a horizontal cleavage lesion in the posterior horn of the medial meniscus.
The purpose of this study was to determine if a horizontal cleavage lesion (HCL) of the posterior horn of the medial meniscus would result in changes to tibiofemoral contact mechanics, as measured by peak contact pressure and contact area, which can lead to cartilage degeneration. To study this, 10 cadaveric knees were tested in a rig where forces were applied (500 N Compression, 100 N shear, 2...
متن کاملTibiofemoral Contact Mechanics with Horizontal CleavageTears and Resection of the Lateral Meniscus in the Human Knee
This open‐access article is published and distributed under the Creative Commons Attribution ‐ NonCommercial ‐ No Derivatives License (http://creativecommons.org/licenses/by‐nc‐nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article w...
متن کاملAltered tibiofemoral contact mechanics due to lateral meniscus posterior horn root avulsions and radial tears can be restored with in situ pull-out suture repairs.
BACKGROUND An avulsion of the posterior root attachment of the lateral meniscus or a radial tear close to the root attachment can lead to degenerative knee arthritis. Although the biomechanical effects of comparable injuries involving the medial meniscus have been studied, we are aware of no such study involving the lateral meniscus. We hypothesized that in situ pull-out suture repair of latera...
متن کاملEffect of lateral meniscectomy and osteochondral grafting of a lateral femoral condylar defect on contact mechanics: a cadaveric study in dogs
BACKGROUND Osteochondral autograft transfer (OAT) aims at restoring normal articular cartilage surface geometry and articular contact mechanics. To date, no studies have evaluated the contact mechanics of the canine stifle following OAT. Additionally, there are no studies that evaluated the role of the meniscus in contact mechanics following OAT in human or canine femorotibial joints. The objec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical biomechanics
دوره 24 8 شماره
صفحات -
تاریخ انتشار 2009