The radio spectrum and magnetic field structure of SNR HB3
نویسندگان
چکیده
Context. Evidence for a spectral flattening of the supernova remnant (SNR) HB3 (G132.7+1.3) was claimed based on previously published total flux density data, and that flattening was further interpreted as the discovery of thermal bremsstrahlung emission in the shell of HB3. Aims. A spectral flattening has never been observed from any SNR before. Reliable observations of HB3 at frequencies above 3000 MHz are crucial to confirm such a spectral behaviour. Methods. We extracted 4800 MHz total intensity and polarisation data of HB3 from the Sino-German 6 cm polarisation survey of the Galactic plane made with the Urumqi 25 m telescope, and analysed the spectrum of HB3 together with Effelsberg data at 1408 MHz and 2695 MHz. Results. We found an overall spectral index of HB3 of α = −0.61±0.06 between 1408 MHz and 4800 MHz, similar to that at lower frequencies. There is no spectral flattening at high frequencies. We detected strong polarised emission from HB3 at 4800 MHz. Our 4800 MHz data show a tangential field orientation in the HB3 shell.
منابع مشابه
Radio Spectral Index Variations of the SNR HB3
We present images of the SNR HB3 at both 408 MHz and 1420 MHz from the Canadian Galactic Plane Survey mainly based on data from the Synthesis Telescope of the Dominion Radio Astrophysical Observatory. We reproduce the 100m-Effelsberg HB3 image at 2695 MHz at large scale, and find that there exists a background emission gradient across the HB3 area. Based on our analysis of background emission a...
متن کاملNon-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)
Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...
متن کاملThe Measurement of Low Frequency Magnetic Field of Two Kinds of GSM900 Mobile Phone
Introduction: The use of mobile communication systems has dramatically increased over the past decade. Although many studies have been performed to determine the effect of radio frequency (RF) but less attention has been paid to the possible biological impact of exposure to extremely low frequency (ELF) components. The objective of this study is two folds. One is to design the ...
متن کاملRadio polarimetric imaging of the interstellar medium : magnetic field and diffuse ionized gas structure near the W 3 / W 4 / W 5 / HB 3 complex
We have used polarimetric imaging to study the magneto-ionic medium of the Galaxy, obtaining 1420MHz images with an angular resolution of 1′ over more than 40 square-degrees of sky around the W3/W4/W5/HB3 H ii region/SNR complex in the Perseus Arm. Features detected in polarization angle are imposed on the linearly polarized Galactic synchrotron background emission by Faraday rotation arising i...
متن کاملRadio properties of the low surface brightness SNR G 65 . 2 + 5 . 7 ⋆
Context. SNR G65.2+5.7 is one of few supernova remnants (SNRs) that have been optically detected. It is exceptionally bright in X-rays and the optical [O III]-line. Its low surface brightness and large diameter ensure that radio observations of SNR G65.2+5.7 are technically difficult and thus have hardly been completed. Aims. Many physical properties of this SNR, such as spectrum and polarizati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008