Interference by ascorbic acid in test systems involving peroxidase. I. Reversible indicators and the effects of copper, iron, and mercury.

نویسنده

  • R H White-Stevens
چکیده

I describe the mechanism whereby ascorbic acid can hamper test systems involving a peroxide-generating system, peroxidase, and a benzidine-type indicator. In test media such as urines, abnormally high concentrations of ascorbic acid may give rise to false negatives in the determination of analytes such as glucose. Absorbance measurements in solution or reflectance measurements on commercially available paper reagent strips demonstrate either inhibition of visible activity by ascorbic acid or a lag time in the development of oxidized indicator color. The duration of the lag time is proportional to the ascorbic acid concentration, is inversely proportional to the enzyme concentration, and is also affected by concentrations of hydrogen peroxide and o-tolidine indicator. The same results were seen in both citrate buffer pH 5 and phosphate buffer pH 7. Because the complete system (o-tolidine indicator, hydrogen peroxide, and peroxidase) must be present if the ascorbate is to be oxidized rapidly, this indicates that ascorbic acid inhibits color development by re-reducing oxidized indicator as fast as it is formed; the o-tolidine then acts catalytically in oxidizing ascorbic acid. Added Cu2+ and Fe3+, both known to react with ascorbic acid, had measurable but small effects on the system. In contrast, Hg2+ abolished the ascorbic acid-elicited lag time, even when present in near-stoichiometric concentration. Hg2+ showed little inhibitory effect on the activity of either glucose oxidase or peroxidase. Presumably it rapidly oxidizes ascorbic acid to dehydroascorbate. The reaction of mercuric ion with ascorbate was measured by reflectance measurements of paper reagent strips in addition to absorbance measurements of solution assays; equivalent results were obtained. Incorporation of Hg2+ into reagent strips can thus render both strips and solution diagnostic tests insensitive to interfering substances such as ascorbic acid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of L- Ascorbic Acid in Plasma by Voltammetric Method

Voltammetric techniques have been considered as important methods among the analytical techniques used for the identification and determination of trace concentrations of many biological molecules such as L-ascorbic acid (AA). L-ascorbic acid is an electro-active molecule, though it is difficult to determine its value directly with a majority of electrodes made of carbon and transition metals, ...

متن کامل

Determination of L- Ascorbic Acid in Plasma by Voltammetric Method

Voltammetric techniques have been considered as important methods among the analytical techniques used for the identification and determination of trace concentrations of many biological molecules such as L-ascorbic acid (AA). L-ascorbic acid is an electro-active molecule, though it is difficult to determine its value directly with a majority of electrodes made of carbon and transition metals, ...

متن کامل

Alleviation of Adverse Effects of Copper on Allium cepa L. by Exogenous Ascorbic Acid Application

Abstract In this study ameliorative effects of ascorbic acid (0.5 mM) on onion (Allium cepa L. cv. Red Azarshahr) under copper stress (Cu: 6.5 μM) were studied. Fresh weights of leaves and roots were reduced in seven week old plants under excess copper condition. Cu stress also reduced membrane stability index in leaves. There was a considerable increase in H2O2 content and lipid peroxidation i...

متن کامل

EFFECTS OF SOME NOVEL ASCORBIC ACID-METAL COMPLEXES ON SELECTED BACTERIAL AND FUNGAL SPECIES

The antimicrobial activity of some novel ascorbic acid-metal complexes [bisascorbate complexes of copper (II), zinc(II), manganese (11), iron (111), cobalt(II), lead(II) and cadmium(II)] was investigated. Four standard strains of bacterial species - Staphylococcus aureus, Escherichia coli, Bacillus subtilis and Klebsiella pneumonia and four fungal species - Trichophyton sp. Penicillium sp....

متن کامل

Indirect potentiometric titration of ascorbic acid in pharmaceutical preparations using copper based mercury film electrode.

A simple and rapid potentiometric method for the estimation of ascorbic acid in pharmaceutical dosage forms has been developed. The method is based on treating ascorbic acid with iodine and titration of the iodide produced equivalent to ascorbic acid with silver nitrate using Copper Based Mercury Film Electrode (CBMFE) as an indicator electrode. Interference study was carried to check possible ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 4 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1982