Is “Silent Ischemia” Detectable by Endocardial Pacemaker Leads?
نویسندگان
چکیده
The purpose of the following pilot study is to evaluate the possibility to detect the asymptomatic ischemic episodes which often precede dangerous events by means of endocardial signals. Intracardiac electrograms (IEGMs) have been detected in patients undergoing percutaneous transluminal coronary angioplasty (PTCA), a procedure during which ischemic episodes are induced. For 10 patients IECGs have been examined and compared with the surface 12-lead ECGs, used in current clinical practice to make a diagnosis of ischemia. This work takes part in a project (Body Worn) aimed at planning a prompt aid system for patients at high cardiovascular risk implanted with a pacemaker. In case of abnormalities in the endocardial signals detected by pacemaker leads, the intervention procedure is tought to be activated. However, results from primary data show that a diagnosis of silent ischemia cannot be made on the basis of the only IEGMs.
منابع مشابه
Cardiac Innervation and Sudden Cardiac Death
The heart is extensively innervated and its performance is tightly controlled by the nervous system. Cardiac innervation density varies in diseased hearts leading to unbalanced neural activation and lethal arrhythmia. Diabetic sensory neuropathy causes silent myocardial ischemia, characterized by loss of pain perception during myocardial ischemia, which is a major cause of sudden cardiac death ...
متن کاملApplication of Anatomical and Functional Modalities in Detection of Silent Myocardial Ischemia in Asymptomatic Diabetic Patients- A Review Article
Cardiovascular disease (CAD) screening in asymptomatic patients with diabetes mellitus is controversial. An exercise stress test is a safe and effective initial testing for Ischemic Heart Disease (IHD) screening. Treadmill stress test is not the best screening method for a particular patient who is not able to exercise, abnormal electrocardiogram (ECG) or positive exercise treadmill test (ETT) ...
متن کاملPacemaker lead related tricuspid stenosis: a report of two cases.
Only four cases of tricuspid stenosis related to endocardial pacemaker leads have been reported. Two further cases associated with perforation of a tricuspid valve leaflet by a pacemaker lead are presented: a 46 year old woman and a 60 year old man. It is possible that tricuspid valve disease related to endocardial pacemaker and non-thoracotomy defibrillator leads is underrecognized. Diagnosis ...
متن کاملDisplacement of pacemaker leads--a 10-year survey.
Displacement of endocardial pacemaker leads from the initial site at the time of implantation is a major cause of unpredictable pacemaker failure. In this survey, we have made a retrospective study of the effectiveness of the attempts made by two manufacturers to design leads to reduce the frequency of this occurrence. The cumulative displacement records of 5 types of leads (Medtronic types 581...
متن کاملEndocardial Pacemaker Implantation in Neonates and Infants
Transvenous pacemaker lead implantation is the preferred method of pacing in adult patients. Lead performance and longevity are superior and the implantation approach can be performed under local anaesthetic with a very low morbidity. In children, and especially in neonates and infants, the epicardial route was traditionally chosen until the advent of smaller generators and lead implantation te...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008