Aortic cannula velocimetry.
نویسندگان
چکیده
Robert C Groom, Aaron G Hill The Virginia Heart Center at Fairfax Hospital, Falls Church, Virginia, Barry Kuban The Ohio State University Department of Biomedical Engineering, Columbus, Ohio, William Oneill 3M Cardiovascular, Incorporated, Ann Arbor, Michigan, Bechara F Akl, Alan M Speir, James Koningsberg, Gregory T Sprissler, Mohamed Shakoor, Paul S Massimiano, Nelson A Burton, Robert A Albus, Quentin Macmanus and Edward A Lefrak The Virginia Heart Center
منابع مشابه
Novel emboli protection cannula during cardiac surgery: first animal study.
BACKGROUND Stroke after open heart surgery is a major cause of morbidity and mortality. Up to 60% of intraoperative cerebral events are caused by emboli generated by manipulations of the aorta during surgery. This is the first animal study evaluating the safety and efficacy of a novel aortic cannula designed to extract solid and gaseous emboli during cardiac surgery. METHODS Seven domestic pi...
متن کاملComputational fluid dynamic analysis to prevent aortic root and valve clots during left ventricular assist device support.
Aortic root and valve clots are rare but well described in patients on maximal left ventricular assist device (LVAD) support. We performed a theoretical analysis using computational fluid dynamic analyses in two dimensions to try and ascertain if inflow cannula design/orientation/placement affect aortic root flow dynamics. Two-dimensional computational fluid dynamics using easy CFD-G was perfor...
متن کاملThe "sandblasting" effect of aortic cannula on arch atheroma during cardiopulmonary bypass.
A 69-yr-old woman presented with dyspnea on exertion was found to have moderate-to-severe mitral regurgitation with moderate left ventricular dysfunction (estimated ejection fraction was 30%) and was scheduled for elective mitral valve repair. The patient had undergone uneventful coronary artery bypass graft surgery 7 months earlier. Her medical history was otherwise significant for hypertensio...
متن کاملImproved hydrodynamics of a new aortic cannula with a novel tip design.
BACKGROUND Reduction of atheroembolic complications during cardiopulmonary bypass remains a major challenge in cardiac surgery. New cannula tip designs may help to attenuate this problem by improved hydrodynamics. METHODS Pressure gradients and back pressures of a new aortic cannula tip design were measured and compared with the Medos X-Flow, Sarns Soft-Flow and Argyle THI cannulae at various...
متن کاملNeonatal aortic arch hemodynamics and perfusion during cardiopulmonary bypass.
The objective of this study is to quantify the detailed three-dimensional (3D) pulsatile hemodynamics, mechanical loading, and perfusion characteristics of a patient-specific neonatal aortic arch during cardiopulmonary bypass (CPB). The 3D cardiac magnetic resonance imaging (MRI) reconstruction of a pediatric patient with a normal aortic arch is modified based on clinical literature to represen...