Protective Effect of Adhesive Systems associated with Neodymium-doped Yttrium Aluminum Garnet Laser on Enamel Erosive/Abrasive Wear.

نویسندگان

  • Erica Crastechini
  • Alessandra B Borges
  • Klaus Becker
  • Thomas Attin
  • Carlos Rg Torres
چکیده

AIM This study evaluated the efficacy of self-etching adhesive systems associated or not associated with the neodymium-doped yttrium aluminum garnet (Nd:YAG) laser on the protection against enamel erosive/abrasive wear. MATERIALS AND METHODS Bovine enamel specimens were demineralized with 0.3% citric acid (5 minutes). The samples were randomly assigned to eight groups (n = 20): SB - Single Bond Universal (3M/ESPE); SB+L - Single Bond Universal + laser (80 mJ/10 Hz); FB - Futurabond U (Voco); FB+L -Futurabond U + laser; GEN - G-aenial bond (GC); GEN+L -G-aenial bond + laser; L - laser irradiation; and C - no treatment. The laser was applied before light curing. The samples were subjected to erosive/abrasive challenges (0.3% citric acid - 2 minutes and tooth brushing four times daily for 5 days). Enamel surface loss was recovered profilometrically by comparison of baseline and final profiles. The adhesive layer thickness, retention percentage of the protective layer, and microhardness of cured adhesive were measured. Data were analyzed using one-way analysis of variance and Tukey's test (5%). RESULTS There were significant differences for all parameters (p = 0.0001). Mean values ± SD and results of the Tukey's test were: Surface wear: GEN - 4.88 (±1.09)a, L - 5.04 ± 0.99)a, FB - 5.32 (±0.93)ab, GEN + L - 5.46 (±1.27)abc, SB + L - 5.78 (±1.12)abc, FB + L - 6.23 (±1.25)bc, SB - 6.35 (±1.11)c, and C - 6.46 (±0.61)c; layer thickness: GEN - 15.2 (±8.63)c, FB - 5.06 (±1.96)a, GEN + L - 13.96 (±7.07)bc, SB + L - 4.24 (±2.68)a, FB + L - 9.03 (±13.02)abc, and SB - 7.49 (±2.80)ab; retention: GEN - 68.89 (±20.62)c, FB - 54.53 (±24.80)abc, GEN + L - 59.90 (±19.79)abc, SB + L - 63.37 (±19.30)bc, FB + L - 42.23 (±17.68) a, and SB - 47.78 (±18.29)ab; microhardness: GEN - 9.27 (±1.75)c; FB - 6.99 (±0.89)b; GEN + L - 6.22 (±0.87)ab; SB + L - 15.48 (±2.51)d; FB + L - 10.67 (±1.58)c; SB - 5.00 (±1.60)a. CONCLUSION The application of Futurabond U and G-aenial bond on enamel surface, as well as the Nd:YAG laser irradiation alone, was able to reduce the enamel wear. The use of laser after the adhesive systems did not improve their efficacy. CLINICAL SIGNIFICANCE Erosive/abrasive wear is a prevalent condition in clinical practice affecting many patients. The association of adhesive systems and Nd:YAG laser is of considerable clinical interest because it assesses new treatments to reduce the erosive/abrasive wear that would help dentists in clinical treatment decisions to reduce enamel wear and achieve a successful treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro Evaluation of Dentin Surface Irradiated by Neodymium-doped: Yttrium Aluminum Garnet Laser (Nd: YAG) Using Scanning Electron Microscopy

Introdouction: Dentinal hypersensitivity (DH) is one of the most painful chronic problems reported in dental offices. Various methods have been applied for the treatment of DH. However, majority of them are either ineffective or last for a short period of time. It has been reported that lasers, particularly Neodymium- doped: Yttrium Aluminum Garnet laser (Nd: YAG), can be helpful in the treatme...

متن کامل

Random Laser Action in Nd:YAG Crystal Powder

This work explores the room temperature random stimulated emission at 1.064 μm of a Nd:YAG crystal powder (Neodymium-doped yttrium aluminum garnet) in a very simple pump configuration with no assistance from an internal mirror. The laser threshold energy as a function of pump beam area and pump wavelength has been measured, as well as the temporal dynamics of emission pulses. The absolute energ...

متن کامل

Data Fitting to Study Ablated Hard Dental Tissues by Nanosecond Laser Irradiation

Laser ablation of dental hard tissues is one of the most important laser applications in dentistry. Many works have reported the interaction of laser radiations with tooth material to optimize laser parameters such as wavelength, energy density, etc. This work has focused on determining the relationship between energy density and ablation thresholds using pulsed, 5 nanosecond, neodymium-doped y...

متن کامل

Localized flap melt after Nd-YAG laser treatment in recurrent post-LASIK epithelial ingrowth.

Neodymium: Yttrium-Aluminum-Garnet (Nd-YAG) laser treatment of epithelial ingrowth was found promising with high success rates in cases of primary post-LASIK epithelial ingrowth. However, the application range of this procedure is not well-known. For the first time, the authors report the outcome of a patient treated with Nd-YAG laser for multiple recurrences of post-laser in situ keratomileusi...

متن کامل

Intraocular Pressure Spikes following Neodymium-doped Yttrium Aluminum Garnet Laser Capsulotomy: Current Prevalence and Management in Israel

AIM The current treatment for posterior capsular opacification (PCO), neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy, may lead to increased intraocular pressure (IOP). Our aim was to survey routines in the management of IOP spikes and to identify the rate of IOP spikes following prophylactic apraclonidine treatment. MATERIALS AND METHODS A survey questionnaire among ophtha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 18 10  شماره 

صفحات  -

تاریخ انتشار 2017