Evaluation of the TriSpan neck bridge device for the treatment of wide-necked aneurysms: an experimental study in canines.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Many wide-necked aneurysms are difficult or impossible to treat with the Guglielmi detachable coil (GDC). The purpose of this study was to evaluate the use of a neck bridging device, the TriSpan coil, in combination with standard GDCs for the treatment of wide-necked aneurysms in an experimental canine aneurysm model. METHODS Of 24 experimental aneurysms in 12 animals, 19 (7 lateral and 12 terminal) were treated with the TriSpan coil in conjunction with standard GDCs. Digital subtraction angiography (DSA) was performed on all animals immediately after treatment. In 6 animals, follow-up DSA and histological evaluation were performed 4 weeks after treatment. In the remaining 6, DSA was done at both 90 and 180 days after treatment. Histological evaluation was done immediately after the 180-day angiographic evaluation. RESULTS The TriSpan was easy to use in conjunction with the standard GDC. Because of their geometry, some lateral aneurysms were difficult or impossible to treat with this device. Greater than 90% aneurysm occlusion was obtained in all 19 aneurysms. In no instance was there evidence of coil migration, herniation, or aneurysm recanalization. Histological evaluation of the tissue surrounding the TriSpan coil showed tissue responses similar to that seen with standard GDCs. CONCLUSIONS These results show that the TriSpan coil in conjunction with standard GDCs can be used safely and effectively for the treatment of wide-necked aneurysms in this canine model. Positioning and deployment of the neck bridge in aneurysms having an acute angle with the long axis of their parent artery are difficult or impossible. It is likely that this device, used in conjunction with the standard GDC, will allow treatment of some wide-necked aneurysms that are not treatable with the GDC alone.
منابع مشابه
Evaluation of a neck-bridge device to assist endovascular treatment of wide-neck aneurysms of the anterior circulation.
BACKGROUND AND PURPOSE Intracranial aneurysms with a wide-neck or an unfavorable dome-to-neck ratio may be difficult to treat properly and safely. Our aim was to evaluate the TriSpan neck-bridge device to assist coiling of wide-neck bifurcation aneurysms in the anterior circulation. MATERIALS AND METHODS In 14 patients, we performed 16 TriSpan-assisted coil embolizations with wide-neck bifurc...
متن کاملEvaluation of a Neck-Bridge Device to Assist Endovascular Treatment of Wide-Neck Aneurysms of the Anterior Circulation
MATERIALS AND METHODS: In 14 patients, we performed 16 TriSpan-assisted coil embolizations with wide-neck bifurcation aneurysms of the anterior circulation. Eleven procedures were indicated for acutely ruptured aneurysms. Five were performed electively for the following: recurrent aneurysm after coil only (n 1) or after TriSpan-assisted embolization (n 2), aneurysm remnant after clipping (n 1),...
متن کاملUse of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms.
A three-dimensional Guglielmi detachable coil (3D-GDC) has been developed that is designed specifically to bridge the neck of an aneurysm with coil loops, thereby facilitating retention of additional coils placed within the aneurysm. Nine wide-necked cerebral aneurysms were successfully embolized using the 3D-GDC, provided that the dome-to-neck ratio was 1.5 or greater.
متن کاملEndovascular treatment of experimental wide neck aneurysms: comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device.
BACKGROUND AND PURPOSE Endovascular treatment of wide neck aneurysms often results in incomplete occlusion or aneurysm recurrence. The two goals of the present study were to compare results of coil embolization with or without the assistance of an aneurysm neck bridge device (ANBD) and to explore the use of this instrument to control cyanoacrylate embolization. METHODS Wide necked bifurcation...
متن کاملCombined stent implantation and endosaccular coil placement for treatment of experimental wide-necked aneurysms: a feasibility study in swine.
PURPOSE To assess the feasibility of combining stent implantation in the parent artery with endosaccular coil placement for the treatment of experimentally created wide-necked aneurysms. METHODS Wide-necked aneurysms were surgically created on the common carotid artery in 12 swine. A metal stent was endovascularly implanted across each aneurysm neck and its effect documented anigiographically...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Stroke
دوره 32 2 شماره
صفحات -
تاریخ انتشار 2001