Endoscopy and implantable electronic devices.

نویسندگان

  • G D Corbett
  • P C Buttery
  • P J Pugh
  • E A B Cameron
چکیده

The increasing use of implantable electronic devices such as cardiac pacemakers and neurostimulators means that they are being increasingly encountered in endoscopy departments. The electromagnetic fields generated during electrosurgery and with magnetic imaging systems have the potential to interfere with such devices. The authors present a case that highlights some of the steps necessary for minimising risk, review the evidence and summarise the currently available guidance.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Capsule endoscopy in patients with cardiac pacemakers, implantable cardioverter defibrillators and left heart assist devices

According to the recommendations of the US Food and Drug Administration and manufacturers, capsule endoscopy should not be used in patients carrying implanted cardiac devices. For this review we considered studies indexed (until 30.06.2013) in Medline [keywords: capsule endoscopy, small bowel endoscopy, cardiac pacemaker, implantable cardioverter defibrillator, interference, left heart assist d...

متن کامل

Capsule Endoscopy in Patients with Cardiac Pacemakers, Implantable Cardioverter Defibrillators, and Left Heart Devices: A Review of the Current Literature

Background and Study Aims. Capsule endoscopy is an established tool for investigation of the small intestine. Because of limited clinical experience in patients with cardiac devices, the Food and Drug Administration and the manufacturer recommended not to use capsule endoscopy in these patients. The vast majority of investigations did not reveal any interference between capsule endoscopy and ca...

متن کامل

Capsule Endoscopy in a Patient with an Implanted CCM System and an Implantable Defibrillator

Wireless video capsule endoscopy (CE) is a modern diagnostic tool. Because of its use of digital radiofrequency, it is still relatively contraindicated in patients with implanted cardiac devices. We report the case of a patient with an Optimizer III system delivering cardiac contractility modulating signals (CCM) for heart failure therapy and an implantable cardioverter defibrillator (ICD) who ...

متن کامل

دستگاه‌های کاشت‌پذیر برای کودکان ناشنوا

The idea of providing hearing to profoundly deaf patients by artificially stimulating the sensory system has progressed from a futuristic possibility to reality. Generally, an implantable hearing device is designed to capture sound and present it to the auditory system, where at least part of the device is surgically implanted in the child receiving it. The goal of the implantable devices in yo...

متن کامل

Implantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study

Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important.  ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Frontline gastroenterology

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2012