Accounting for free and restricted diffusion processes in single- and double-PFG experiments using a novel bi-compartmental phantom
نویسندگان
چکیده
Figure 3. Angular d-PFG experiments performed on a bi-compartmental phantom consisting of microcapillaries with inner diameter of 19 μm in the SDC and 20 μl of water in the FDC. The diffusion periods were sufficiently long to probe the boundaries. Symbols represent experimental data, while the solid lines represent the theoretical fitting to the experimental data. Accounting for free and restricted diffusion processes in singleand double-PFG experiments using a novel bicompartmental phantom
منابع مشابه
Observation of restricted diffusion in the presence of a free diffusion compartment: single- and double-PFG experiments.
Theoretical and experimental studies of restricted diffusion have been conducted for decades using single pulsed field gradient (s-PFG) diffusion experiments. In homogenous samples, the diffusion-diffraction phenomenon arising from a single population of diffusing species has been observed experimentally and predicted theoretically. In this study, we introduce a composite bi-compartmental model...
متن کاملAccurate noninvasive measurement of cell size and compartment shape anisotropy in yeast cells using double-pulsed field gradient MR.
The accurate characterization of pore morphology is of great interest in a wide range of scientific disciplines. Conventional single-pulsed field gradient (s-PFG) diffusion MR can yield compartmental size and shape only when compartments are coherently ordered using q-space approaches that necessitate strong gradients. However, double-PFG (d-PFG) methodology can provide novel microstructural in...
متن کاملPersistence of diffusion-diffraction features in double-PFG experiments conducted on size distribution phantoms
One of the most important attributes of diffusion NMR is that it can employ restricted diffusion to probe microstructures of opaque samples. The single-pulsed-field-gradient (s-PFG) methodology (Fig. 1A) employs a pair of diffusion-sensitizing PFGs that are separated by an interval in which the diffusion process takes place. When a specimen is characterized by a very narrow size distribution or...
متن کاملPore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom.
Double pulsed-field gradient (d-PFG) MRI can provide quantitative maps of microstructural quantities and features within porous media and tissues. We propose and describe a novel MRI phantom, consisting of wafers of highly ordered glass capillary arrays (GCA), and its use to validate and calibrate a d-PFG MRI method to measure and map the local pore diameter. Specifically, we employ d-PFG Spin-...
متن کاملO27 Observing Diffusion-Diffraction Patterns in Heterogeneous Specimens Using the Double-PFG NMR Methodology
Specimens Using the Double-PFG NMR Methodology Noam Shemesh 1, Evren Ozarslan 2, Peter Basser 2, Yoram Cohen 1 1 Tel Aviv University, 2 National Institute of Health Discussion Diffusion-diffraction patterns arising from restricted diffusion are extremely important for characterizing pore morphology. In conventional single-PFG (sPFG) NMR experiments, pore size can be directly inferred from the m...