OBJECTIVES To develop comprehensive and reliable radiation-free methods to quantify femoral and acetabular morphology using MRI. METHODS 32 hips (16 subjects, 6 with intra-articular hip disorder (IAHD); 10 controls) were included. A 1.5T magnetic resonance system was used to obtain 3D fat suppressed gradient echo images at the pelvis and distal femora. After acquisition, pelvic images were post-processed to correct for coronal, axial and sagittal rotation. Measurements performed included acetabular version (AV), femoral version (FV), lateral center edge angle (LCEA), femoral neck angle (FNA) and alpha angle (AA) at 3, 2, 1 and 12 o'clock. Two experienced raters, a musculoskeletal radiologist and an orthopaedic physical therapist, and a novice rater, a research assistant, completed reliability testing. Raters measured all hips twice with minimum 2 weeks between sessions. Intraclass Correlation Coefficients were used to determine rater reliability; standard error of measurements was reported to estimate the reasonable limits of the expected error in the different raters' scores. RESULTS Interrater reliability was good to excellent for all raters for AV, FV, FNA, and LCEA (ICCs: 0.82-0.98); good to excellent between experienced raters (ICCs: 0.78-0.86) and poor to good between novice and experienced raters (ICCs: 0.23-0.78) for AA. Intrarater reliability was good to excellent for all raters for AV, FV and FNA (ICCs: 0.93-0.99); for one experienced and novice rater for LCEA (ICCs: 0.84-0.89); moderate to excellent for the experienced raters for AA (ICCs: 0.72-0.89). Intrarater reliability was poor for the second experienced rater for LCEA (ICC: 0.56), due to a single measurement error and for the novice rater for AA (ICCs: 0.17-0.38). CONCLUSION We described MRI methods to comprehensively assess femoral and acetabular morphology. Measurements such as AV, FV and FNA and the LCEA can be made reliably by both experienced and novice raters, however the AA measurement was reliable only among experienced raters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance Imaging Assessment of Hip Abductor after Total Hip Arthroplasty Using a Direct Lateral Approach

Background: Surgical techniques and rehabilitations after total hip arthroplasty (THA) play a significant role in theimprovement of pain and limping. This study aimed to assess hip abductor muscle’s diameter and its strength after 6months postoperative THA performed by Hardinge approach.Methods: After obtaining the patients’ demographic characteristics, the preoperative values...

متن کامل

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging

Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...

متن کامل

An investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter

Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2014