In-Plane Motion Correction in Reconstruction of non-Cartesian 3D-functional MRI

نویسندگان

  • Anette Karlsson
  • Maria Magnusson
  • Olof Dahlqvist Leinhard
  • Peter Lundberg
چکیده

When patients move during an MRI examination, severe artifacts arise in the reconstructed image and motion correction is therefore often desired. An in-plane motion correction algorithm suitable for PRESTO-CAN, a new 3D functional MRI method where sampling of k-space is radial in kx-direction and kz-direction and Cartesian in ky-direction, was implemented in this thesis work. Rotation and translation movements can be estimated and corrected for separately since the magnitude of the data is only affected by the rotation. The data were sampled in a radial pattern and the rotation was estimated by finding the translation in angular direction using circular correlation. Correlation was also used when finding the translation in x-direction and z-direction. The motion correction algorithm was evaluated on computer simulated data, the motion was detected and corrected for, and this resulted in images with greatly reduced artifacts due to patient movements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Motion correction for functional MRI with three‐dimensional hybrid radial‐Cartesian EPI

PURPOSE Subject motion is a major source of image degradation for functional MRI (fMRI), especially when using multishot sequences like three-dimensional (3D EPI). We present a hybrid radial-Cartesian 3D EPI trajectory enabling motion correction in k-space for functional MRI. METHODS The EPI "blades" of the 3D hybrid radial-Cartesian EPI sequence, called TURBINE, are rotated about the phase-e...

متن کامل

Volumetric thermometry

Background/introduction Many applications of thermal therapy would benefit from temperature distribution measurements with high spatial and temporal resolution that cover a large 3D volume. Although MRI can acquire 3D temperature measurements, it is not possible to obtain fully sampled 3D MRI measurements that cover the insonified field of view with sufficient spatial and temporal resolution fo...

متن کامل

Fast Single Breath-hold 3D Abdominal Spiral Imaging with Water / Fat Separation and Off-resonance Correction

Introduction Large volume coverage, short total scan time and robust water/fat separation are important issues in abdominal MRI. Breath-hold approaches are often used to avoid respiratory motion artifacts, which demands for efficient sampling schemes. Spiral imaging is one of them [1], but shows high sensitivity to off-resonance [2]. Image blurring resulting from spatially varying Bo inhomogene...

متن کامل

List-Mode Affine Rebinning for Respiratory Motion Correction in PET Cardiac Imaging

Positron Emission Tomography (PET) is an established functional imaging modality but its practical deployment is hampered by motion artefacts. This paper proposes a method for correcting reconstructed PET images through a list-mode rebinning process. Respiratory motion is compensated for by applying 2D affine transforms to the respiratory gated sequence of line-ofresponse events prior to image ...

متن کامل

GPU accelerated iterative SENSE reconstruction of radial phase encoded whole-heart MRI

Isotropic whole-heart imaging has become an important protocol in simplifying cardiac MRI. The acquisition time can however be a limiting factor when acquiring large field-of-views at high spatial resolutions. To reduce acquisition times, a three-dimensional (3D) acquisition scheme combining Cartesian sampling in the readout direction with a radial sampling scheme in the phase encoding plane, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011