Structural Safety Analysis Based on Seismic Service Conditions for Butterfly Valves in a Nuclear Power Plant
نویسندگان
چکیده
The structural integrity of valves that are used to control cooling waters in the primary coolant loop that prevents boiling within the reactor in a nuclear power plant must be capable of withstanding earthquakes or other dangerous situations. In this study, numerical analyses using a finite element method, that is, static and dynamic analyses according to the rigid or flexible characteristics of the dynamic properties of a 200A butterfly valve, were performed according to the KEPIC MFA. An experimental vibration test was also carried out in order to verify the results from the modal analysis, in which a validated finite element model was obtained via a model-updating method that considers changes in the in situ experimental data. By using a validated finite element model, the equivalent static load under SSE conditions stipulated by the KEPIC MFA gave a stress of 135 MPa that occurred at the connections of the stem and body. A larger stress of 183 MPa was induced when we used a CQC method with a design response spectrum that uses 2% damping ratio. These values were lower than the allowable strength of the materials used for manufacturing the butterfly valve, and, therefore, its structural safety met the KEPIC MFA requirements.
منابع مشابه
Role of Human Factor in Energy Conservation: Case of Bushehr Nuclear Power Plant
Humans are an integral part of power plants, ranging from construction to routine maintenance. Analysis of the presence and performance of the human factor can play an effective role in reducing and/or optimizing the use of energy resources. Therefore, in this research the investigation of the plant operator's presence direction in order to control a type of accident with the implementation of ...
متن کاملSeismic Vulnerability of Special Structures: A Case Study of Toos Power Plant Stack
The assessment of seismic performance of existing structures is becoming an important problem in earthquake engineering. Some important ructures are considerably old and, therefore, their strengths and ductilities are less than strength and ductility demands because of changes in codes and design methodologies. Such structures must be strengthened to resist future earthquakes. First, a structur...
متن کاملSeismic Vulnerability of Special Structures: A Case Study of Toos Power Plant Stack
The assessment of seismic performance of existing structures is becoming an important problem in earthquake engineering. Some important ructures are considerably old and, therefore, their strengths and ductilities are less than strength and ductility demands because of changes in codes and design methodologies. Such structures must be strengthened to resist future earthquakes. First, a structur...
متن کاملSafety Analysis of Spent Fuel Transportation Cask of Bushehr Nuclear Power Plant through the Passing of Fire Tunnel with ANSYS®10.0
The spent fuel assemblies (FAs) of Bushehr Nuclear Power Plant are planed to be transported by TK-13 casks. Each spent fuel transportation cask holds 12 spent FAs and has a thick steel container to provide shielding. The calculations have been performed for FAs with burn ups of 60 MWd/kg and a 3-years cooling period. The ANSYS®10.0 general finite element analysis package was se...
متن کاملRole of Human Factor in Energy Conservation: Case of Bushehr Nuclear Power Plant
Humans are an integral part of power plants, ranging from construction to routine maintenance. Analysis of the presence and performance of the human factor can play an effective role in reducing and/or optimizing the use of energy resources. Therefore, in this research the investigation of the plant operator's presence direction in order to control a type of accident with the implementation of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2014 شماره
صفحات -