Vertebral artery origin stent placement with distal protection: technical and clinical results.

نویسندگان

  • A I Qureshi
  • J F Kirmani
  • P Harris-Lane
  • A A Divani
  • S Ahmed
  • A Ebrihimi
  • A Al Kawi
  • N Janjua
چکیده

OBJECTIVE To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. METHODS We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. RESULTS The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. CONCLUSION The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carotid artery stent placement with distal balloon protection: technical considerations.

BACKGROUND AND PURPOSE Most neurologic events that complicate the carotid artery stent placement procedure are embolic. Strategies are being developed and evaluated for their ability to minimize the clinical embolic risk. The purpose of this study was to determine the feasibility, safety, and technical considerations of performing carotid artery stent placement with use of a distal balloon anti...

متن کامل

Treatment of stenoses of vertebral artery origin using short drug-eluting coronary stents: improved follow-up results.

BACKGROUND AND PURPOSE Recent studies on stent placement of significant stenoses at the origin of the vertebral artery reported excellent immediate results. Long-term outcomes, however, were disappointing due to high restenosis rates and stent breakage. In the present study, we evaluated the application of a short drug-eluting balloon-expandable coronary stent for the endovascular treatment of ...

متن کامل

Percutaneous transluminal angioplasty and stenting of the proximal vertebral artery for symptomatic stenosis.

BACKGROUND AND PURPOSE Percutaneous transluminal angioplasty (PTA) for significant stenosis involving the origin of the vertebral artery is now a well established treatment for selected patients when posterior cerebral arterial circulation is compromised. Arterial spasm, dissection, and restenosis may occur in some instances, with subsequent hemodynamic compromise. To prevent these potential co...

متن کامل

Stenting from the vertebral artery to the posterior inferior cerebellar artery.

BACKGROUND AND PURPOSE There are only a few reports on the feasibility and safety of stents used in the PICA, and clinical and angiographic follow-up results have not been fully addressed. We report our experiences of treating PICA origin or vertebral artery-PICA lesions by using self-expanding stents as adjuvant or rescue therapy with angiographic and clinical follow-up results. MATERIALS AN...

متن کامل

Clinical Implications of Congenital Absence of Circumflex Coronary Artery

Introduction: Coronary artery anomalies are rare clinical entities reported in 0.6% to 5.6% of diagnostic coronary angiographies. Anomalous origins of coronary arteries from distal segments are rarely reported. Presented herein is a coronary anomaly in which the circumflex artery (CX) originated as a continuation of the posterolateral branch of the right coronary artery (RCA) w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 27 5  شماره 

صفحات  -

تاریخ انتشار 2006