Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience

نویسندگان

  • Luciana Caravatta
  • Gabriella Macchia
  • Gian Carlo Mattiucci
  • Aldo Sainato
  • Nunzia LV Cernusco
  • Giovanna Mantello
  • Monica Di Tommaso
  • Marianna Trignani
  • Antonino De Paoli
  • Gianni Boz
  • Maria L Friso
  • Vincenzo Fusco
  • Marta Di Nicola
  • Alessio G Morganti
  • Domenico Genovesi
چکیده

BACKGROUND An observational multi-institutional study has been conducted aimed to evaluate the inter-observer variability in clinical target volume (CTV) delineation among different radiation oncologists in radiotherapy treatment of pancreatic cancer. METHODS A multi-institutional contouring dummy-run of two different cases of pancreatic cancer treated by postoperative and preoperative radiotherapy (RT) was performed. Clinical history, diagnostics, and planning CT imaging were available on AIRO website (http://www.radioterapiaitalia.it). Participants were requested to delineate CTVs according to their skills and knowledge. Aiming to quantify interobserver variability of CTVs delineations, the total volume, craniocaudal, laterolateral, and anteroposterior diameters were calculated. Descriptive statistic was calculated. The 95% Confidence Interval (95% CI) for coefficient of variation (CV) was estimated. The Dice Similarity Index (DSI) was used to evaluate the spatial overlap accuracy of the different CTVs compared with the CTVs of a national reference Centre considered as a benchmark. The mean DSI (mDSI) was calculated and reported. RESULTS A total of 18 radiation oncologists from different Institutes submitted the targets. Less variability was observed for the Elective CTV rather than the Boost CTV, in both cases. The estimated CV were 28.8% (95% CI: 21.2-45.0%) and 20.0% (95% CI: 14.9-30.6%) for the Elective CTV, in adjuvant (Case 1) and neoadjuvant (Case 2) case, respectively. The mDSI value was 0.68 for the Elective CTVs in both cases (range 0.19-0.79 in postoperative vs range 0.35-0.79 in preoperative case). The mDSI was increased to 0.71 (Case 1) and 0.72 (Case 2) if the observers with a worse agreement have been excluded. On the other hand, a CV of 42.4% (95% CI: 30.1-72.4%) and 63.8% (95% CI: 43.9-119.2%) with a mDSI value of 0.44 and 0.52, were calculated for the Boost CTV in Case 1 and Case 2, respectively. CONCLUSIONS The CV and mDSI obtained values for Elective CTVs showed an acceptable agreement among participants either in postoperative as well in preoperative setting. Additional strategies to reduce the variability in Boost CTV delineation need to be found and promoted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Challenges for Quality Assurance of Target Volume Delineation in Clinical Trials

In recent years, new radiotherapy techniques have emerged that aim to improve treatment outcome and reduce toxicity. The standard method of evaluating such techniques is to conduct large scale multicenter clinical trials, often across continents. A major challenge for such trials is quality assurance to ensure consistency of treatment across all participating centers. Analyses from previous stu...

متن کامل

Magnetic resonance imaging in the radiation treatment planning of localized prostate cancer using intra-prostatic fiducial markers for computed tomography co-registration.

PURPOSE To assess the feasibility, and potential implications, of using intra-prostatic fiducial markers, rather than bony landmarks, for the co-registration of computed tomography (CT) and magnetic resonance (MR) images in the radiation treatment planning of localized prostate cancer. METHODS All men treated with conformal therapy for localized prostate cancer underwent routine pre-treatment...

متن کامل

Quantitative assessment of inter-observer variability in target volume delineation on stereotactic radiotherapy treatment for pituitary adenoma and meningioma near optic tract

BACKGROUND To assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise. METHODS We quantitatively analyzed 21 plans made by 11 clinicians in seven CyberKnife centers. The clinicians were provided with a raw data set (pituitary adenoma and meningioma) including clinical information, and were asked ...

متن کامل

Tumour auto-contouring on 2d cine MRI for locally advanced lung cancer: A comparative study

BACKGROUND AND PURPOSE Radiotherapy guidance based on magnetic resonance imaging (MRI) is currently becoming a clinical reality. Fast 2d cine MRI sequences are expected to increase the precision of radiation delivery by facilitating tumour delineation during treatment. This study compares four auto-contouring algorithms for the task of delineating the primary tumour in six locally advanced (LA)...

متن کامل

A New Index to Measure Intra-observer Variation in Delineating GTV Primary in Head and Neck Cancer

A critical step in radiotherapy treatment planning process is to accurately locate the tumor and determine its extent. Variability in gross tumor volume (GTV) delineation is a major source of systematic error in conformal radiotherapy. CT scan is the principle source of imaging data used for defining GTV for planning conformal therapy. CT is widely available less costly and compatible with radi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014