Bias and variability in blood pressure measurement with ambulatory recorders.
نویسندگان
چکیده
This study sought to determine whether patient characteristics such as age, sex, blood pressure, and pulse pressure differently affect the accuracy of an oscillometric (SpaceLabs 90207) and a microphonic (TM2420 version 7) blood pressure monitor. Blood pressure recorded by two oscillometric and two microphonic ambulatory monitors was compared with simultaneous readings by two pairs of trained, blinded observers using random-zero sphygmomanometry. One hundred and eighteen subjects (53 men and 65 women, aged 17 to 94 years; systolic pressure, 89 to 211 mm Hg; diastolic, 44 to 116 mm Hg) were studied. There were no significant differences within each observer pair or between the two observer pairs as well as no correlation between interobserver differences and patient characteristics. The differences between the monitor and trained observers' readings were 2.8 +/- 9.9 mm Hg systolic and 3.9 +/- 6.8 mm Hg diastolic for the SpaceLabs and 5.0 +/- 5.2 mm Hg systolic and 3.4 +/- 6.1 mm Hg diastolic for the TM2420. Patient characteristics that predicted measurement error were defined by multiple regression. For oscillometry, systolic measurement error was highly correlated with systolic pressure, pulse pressure, and subject age. The diastolic error was significantly correlated with pulse pressure, diastolic pressure, and subject sex. For the oscillometric monitor, patient characteristics accounted for 36.6% of the variation of the systolic error and 34.7% of the variation of the diastolic error. For the microphonic monitor, only age correlated with diastolic error, and no significant correlations were seen with systolic error. Patient characteristics accounted for only 1.2% of the systolic and 8.9% of the diastolic error.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Short report: accuracy of the Profilomat ambulatory blood pressure measuring system determined by the British Hypertension Society Protocol.
Objective: To evaluate the Profilomat monitor for ambulatory blood pressure measurement according to the British Hypertension Society (BHS) protocol. Design: The BHS protocol consists of six phases: I, observer training and assessment; II, before-use interdevice variability assesment; Ill, in-use assessment; IV, after-use interdevice variability assessment; V, device validation; and VI, prepara...
متن کاملDo SpaceLabs ambulatory non-invasive blood pressure recorders measure blood pressure consistently over several years use?
OBJECTIVE To assess the measurement consistency of SpaceLabs ambulatory recorders (Spacelabs, Washington, USA) that are in regular use. METHODS A total of 14 SpaceLabs 90207 and one 90217 ambulatory recorders were tested for measurement consistency using the Dynatech CuffLink (Dynatech, Nevada, USA), a commercially available non-invasive blood pressure (NIBP) simulator. The NIBP recorders wer...
متن کاملEffect of unrestricted activity on accuracy of ambulatory blood pressure measurement.
A validation study of the Takeda TM-2420 ambulatory blood pressure recorder was performed on 10 subjects using the Oxford ambulatory intra-arterial recording apparatus during unrestricted activity. Electronic linkage of the two recorders ensured simultaneous blood pressure readings, taken from opposite arms. Although there was close approximation of intra-arterial and automated sphygmomanometri...
متن کاملIncrease of Short-Term Heart Rate Variability Induced by Blood Pressure Measurements during Ambulatory Blood Pressure Monitoring
Objective. The possible effect of blood pressure measurements per se on heart rate variability (HRV) was studied in the setting of concomitant ambulatory blood pressure monitoring (ABPM) and Holter ECG monitoring (HM). Methods. In 25 hypertensive patients (14 women and 11 men, mean age: 58.1 years), 24-hour combined ABPM and HM were performed. For every blood pressure measurement, 2-minute ECG ...
متن کاملEffects of Ramadan fasting on ambulatory blood pressure in hypertensive patients
Background: Previous studies have indicated that Ramadan fasting has beneficial effects on cardiovascular risk factors, specially blood pressure and heart rate. In the present study, the effect of Ramadan fasting on 24-hour ambulatory blood pressure and heart rate has been investigated. Materials and Methods: This prospective observational study was conducted on two groups of individuals. Six p...