In vitro and in vivo evaluation of an oscillometric device for monitoring blood pressure in dialysis patients.
نویسندگان
چکیده
BACKGROUND Nowadays, an increasing number of dialysis machines lodge a blood pressure (BP) measuring device, whose accuracy has a clear implication for the patients' clinical management. METHODS An automated oscillometric sphygmomanometer (HD-BPM by Gambro Dasco) used during haemodialysis was submitted to both in vitro and in vivo tests, in order to evaluate some modifications aimed at improving measurement accuracy and consistency. The results were compared with those obtained by another oscillometric monitor (BX-100 by Colin). Three steps of evaluation were followed. First, the maintenance of the overall accuracy requirements prescribed by ANSI/AAMI SP-10 standard was verified. Then, an in vitro validation was carried out by using a test simulator. Finally, during a multi-centre field trial, 392 BP measurement sessions on 53 dialysis patients were collected. Every session consisted of two consecutive intra-dialysis measurements by the oscillometric monitors, each one performed simultaneously to an auscultatory measurement. A comparison with the intra-arterial method was performed as well. RESULTS When compared with an in vivo data set previously collected, the HD-BPM accuracy complied with required limits. Second, the internal repeatability with respect to the simulator was satisfactory (SD of the differences between device and simulator readings: HD-BPM: systolic = 5.7, diastolic = 4.2; BX-100: systolic = 4.2, diastolic = 5.5 mmHg). Moreover, the comparison between oscillometric and auscultatory methods during in vivo trial gave similar results for the two monitors, even if systolic pressure SD exceeds the limit recommended by ANSI/AAMI SP-10 (mean value of the differences +/- SD: HD-BPM: systolic = 0.5 +/- 9.0, diastolic = 1.5 +/- 6.9; BX-100: systolic = 3.1 +/- 8.2, diastolic = -2.0 +/- 7.6 mmHg). CONCLUSIONS These data underline the importance of performing accuracy evaluations for BP monitors in the conditions where they normally work, by using well-accepted protocols.
منابع مشابه
گزارش یک مورد: ارسال فشار خون و نبض بیمار به پزشک با استفاده از سیستم Global system for Mobile Communications
Background: Hypertension is a common chronic disease with increasing prevalence worldwide. Regular close monitoring of blood pressure is key point of hypertension management. Home monitoring of blood pressure has its own problems such as lack of early access to a physician in case of emergency. In this study we have designed a device that could send the patient’s self-measured blood pre...
متن کاملNano Analysis in Biochemistry: In Vitro Separation and Determination of Aluminium in Blood of Dialysis Patients Based on Graphene Oxide Nanoparticles Dispersed to Ionic Liquid
The highest concentration of aluminium (Al) in human blood has toxic effect and so, extraction from human body is very important. In this procedure, an efficient and new method based on graphene oxide nanoparticles (GONPs) dispersed in ionic liquid (IL) was used for in-vitro separation/extraction of trace Al from the blood of dialysis patients by ultrasound assisted-dispersive-micro solid phase...
متن کاملAn Evaluation of the Effects of Oral Carnitine in Decreasing Complications of Chronic Hemodialysis at Fatemieh Hospital in Semnan
Tamadon MR1, Toussy J2, Soleimani AR3, Moghimi J1, Malek F1, Moradi A4, Shahvarani A5, Tavasoli M5 1. Assistant Professor, Department of Internal, Digestion and Hepatology Research Center, Semnan University of Medical Sciences 2. Statistics Counselor, Digestion and Hepatology Research Center, Semnan University of Medical Sciences 3. Assistant Professor, Department of Internal, Kashaan Universit...
متن کاملIn Vitro and in Vivo studies of the Effects of Cold Argon Plasma on Decreasing the Coagulation Time
Introduction Cold plasma is a self-sterilized, painless, and non-contact method in surgeries. These properties allow it to be applied to the living tissues and heat-sensitive parts. The aim of this study was to design a new cold plasma producer device and evaluate the effects of cold argon plasma on decreasing the coagulation time of blood drop in vitro and that of the injured liver blood in vi...
متن کاملContinuous and Cuffless Blood Pressure Monitoring Based on ECG and SpO2 Signals By Using Microsoft Visual C Sharp
Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 22 10 شماره
صفحات -
تاریخ انتشار 2007