Semiautomated turbidimetric microbiological assay for determination of cefazolin.

نویسندگان

  • D Pitkin
  • P Actor
  • W Holl
  • A Post
  • J A Weisbach
چکیده

The Autoturb System, a semiautomated system for photometric bioassay, was used to determine cefazolin content. Suitable conditions for the assay using Streptococcus faecalis ATCC 10541 as the indicator organism included a medium pH of 6.0 to 7.0 and an incubation time of 3 to 3.5 h at 36 C. Multiple independent assays of samples from a common batch showed the test to be highly reproducible. Accuracy of the turbidimetric assay was evaluated by comparing data obtained from a chemical (hydroxylamine) and a biological (disk diffusion) assay. The available data show the turbidimetric assay to be a rapid, accurate, and reproducible method for determining the biological activity of cefazolin samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel and rapid microbiological assay for ciprofloxacin hydrochloride

The present work reports a simple, fast and sensitive microbiological assay applying the turbidimetric method for the determination of ciprofloxacin hydrochloride (CIPRO HCl) in ophthalmic solutions. The validation method yielded good results and included excellent linearity, precision, accuracy and specificity. The bioassay is based on the inhibitory effect of CIPRO HCl upon the strain of Stap...

متن کامل

Rapid analysis of cefazolin in serum by high-pressure liquid chromatography.

A high-pressure liquid chromatography (HPLC) method has been developed for the analysis of cefazolin in serum. Serum was deproteinized by the addition of 6% trichloroacetic acid and injected onto a reverse-phase column with a mobile phase of 10 to 15% methanol in 1% aqueous acetic acid. Cefazolin chromatographed without interference from ultraviolet-absorbing components of serum, with a retenti...

متن کامل

Comparative study of responses to neomycins B and C by microbiological and gas-liquid chromatographic assay methods.

The relative responses of neomycins B and C have been determined by a microbiological agar-diffusion method, a turbidimetric method, and by a recently developed gas-liquid-chromatographic (GLC) method capable of separating the neomycin isomers. The ratios of response of neomycin C to neomycin B by the individual methods were as follows: agar-diffusion method, 1:3; turbidimetric method, 1:2.5; a...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

Comparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma

An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 1974