Numerical simulation of RF catheter ablation for the treatment of arterial aneurysm.
نویسندگان
چکیده
Considering the blood coagulation induced by the heating of radio frequency ablation (RFA) and the mechanism of aneurysm embolization, we proposed that RFA may be used to treat arterial aneurysm. But the safety of this method should be investigated. A finite element method (FEM) was used to simulate temperature and pressure distribution in aneurysm with different electrode position, electric field intensity and ablation time. When the electrode is in the middle of the artery aneurysm sac, temperature rose clearly in half side of artery aneurysm, which is not suitable for RFA. Temperature rose in the whole aneurysm when the electrode is under the artery aneurysm orifice, which is suitable for the ablation therapy. And in this way, the highest temperature was 69.585°C when power was 5.0 V/mm with 60 s. It can promote the coagulation and thrombosis generation in the aneurysm sac while the outside tissue temperature rises a little. Meanwhile, the pressure (10 Pa) at the top of aneurysm sac with electrode insertion is less than that (60 Pa) without electrode, so electrode implant may protect the aneurysm from rupture. The results can provide a theoretical basis for interventional treatment of aneurysm with RFA.
منابع مشابه
کاربرد انرژی رادیوفرکونسی در درمان آریتمی AVNRT
AV-node modification by catheter RF energy delivery is treatment of choice in the symptomatic patients with AVNRT. This study included 30 patients with AVNRT (19 women, 11 men). We did slow pathway ablation in 29 cases successfully. Maximum effective energy delivery was 40 watts for 40 msec. 1:1 AV conduction increased from 290±40 msec before ablation to 340±65 msec after ablation. Also AV-node...
متن کاملA systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia
Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system. Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...
متن کاملRadiofrequency catheter ablation in the treatment of Wolff-Parkinson-White syndrome
Introduction: Tachyarrhythmias in Wolf Parkinson White (WPW) syndrome, can be a life threatening factor. Antiarrhythmic drug therapy in this syndrome, has not been completely acceptable. Efficacy, safety and economy of Radio Frequency Catheter Ablation (RFCA) in western studies, has made it as the treatment of choice. In the present study, efficacy of RFCA in the ablation of accessory pathway...
متن کاملPulmonary Embolism as a Complication after radiofrequency catheter ablation Study: A Case Report
Pulmonary thromboembolism (PTE) is a fatal condition that may rarely occur due to complications of coronary catheter insertion. In this case report, a 41-year-old male was presented 48 hours after radiofrequency catheter ablation(RFCA) for the management of Wolf-Parkinson-White syndromewith acute onset of dyspnea, hemoptysis, and chest pain. The physical examination revealed coarse crackles in ...
متن کاملI-46: Radiofrequency Ablation of Uterine Fibroids
Uterine fibroids are benign solid tumors that are present in the majority of women. While often asymptomatic, fibroids can result in abnormal uterine bleeding, pelvic pressure, pain, subfertility, dyspareunia and other symptoms. Submucous and intramural fibroids are most associated with heavy menstrual bleeding; subserosal fibroids are more often innocuous unless sufficiently large so as to con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Bio-medical materials and engineering
دوره 26 Suppl 1 شماره
صفحات -
تاریخ انتشار 2015