Analysis of Tclp Extracts by X-ray Fluorescence

نویسندگان

  • Douglas S. Kendall
  • Benjamin A. Burns
  • Jennifer A. Suggs
  • John J. Mackey
چکیده

The toxicity characteristic leaching procedure (TCLP) is one test used by the U.S. Environmental Protection Agency (EPA) to determine if a waste material is hazardous; the TCLP test is widely used by the environmental testing community. The elements of concern for toxicity are arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver. As an environmental forensic laboratory, the National Enforcement Investigations Center (NEIC) of EPA often conducts TCLP testing. It is our practice to confirm TCLP test results that may indicate a violation of a regulation with an alternate technique. This project explored the use of X-ray fluorescence (XRF) as a confirmation technique for the determination of inorganic elements in TCLP extracts. The sample preparation approach investigated was the microliter droplet on filter paper technique. The sample carriers were analyzed under vacuum with a conventional wavelength dispersive XRF spectrometer. Results indicated that TCLP extract analysis by XRF using filters compares well to analysis by inductively coupled plasma-optical emission spectroscopy (ICP-OES). In real-world samples, correlations of 0.98 and 0.94 were achieved for lead and cadmium analyses by XRF and ICPOES, supporting our intent to use XRF as a confirmation technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of hemolysis, osmotic fragility and fluorescence anisotropy on irradiated red blood cells as a function of kV of medical diagnostic X-rays

Background: People occasionally undergo medical diagnostic X-ray examinations and expose their red blood cells to radiation. Radiation that is generated from medical diagnostic X-ray machines is widely used in medical diagnoses. One of the important parameters is kilo-voltage (kV) that is applied across the X-ray tube in medical diagnostic X-ray machines. Kilo-voltage influences the radiation d...

متن کامل

تهیه نانوپودر نیترید سیلیسیم تحت دو مرحله آسیاب‌کاری مکانیکی و عملیات حرارتی

In this study, synthesis of silicon nitride by mechanical alloying and the effects of important parameters of milling time and heat treatment temperature, time and rate are presented. Silicon micro powder and nitrogen gas were used as precursor materials. Synthesized phases, morphology and particle size were investigated by X-ray diffraction pattern (XRD) and Field emission scanning electron mi...

متن کامل

Investigation and Measurement of Ash Content of Coal in Zirab Coal Mine-Iran Using Dual Energy -Ray and X-Ray Fluorescence Methods

Coal with low ash content has an important role in the coal and steel industry. There are different methods to measure the ash content. The conventional method which is used in most coal mines of Iran, is to burn the coal and measure the remaining ash. A new method has been recently developed at Nuclear Research Center (NRC) of Iran, Which works on the basis of the absorption of the dual en...

متن کامل

Thermal Analysis: A Complementary Method to Study the Shurijeh Clay Minerals

Clay minerals are considered the most important components of clastic reservoir rock evaluation studies. The Shurijeh gas reservoir Formation, represented by shaly sandstones of the Late Jurassic-Early Cretaceous age, is the main reservoir rock in the Eastern Kopet-Dagh sedimentary Basin, NE Iran. In this study, X-ray diffraction (XRD), X-ray fluorescence (XRF), scanning electron microscopic (S...

متن کامل

Determining the Content of Silicon Dioxide in Bauxites Using X-Ray Fluorescence Spectrometry

The X-ray fluorescence spectrometry and the MA.BM.006 reference spectrophotometric methods were used to determine the content of SiO2 (%) in bauxites from different deposits. The treatment of samples prior to the analysis involved the following steps: annealing, melting using the borax method,  and the formation of beads. Certified reference bauxite samples were used for the cali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012