Measurements of recirculation during neonatal veno-venous extracorporeal membrane oxygenation: clinical application of the ultrasound dilution technique.

نویسندگان

  • David Clements
  • Johanna Primmer
  • Pamela Ryman
  • Bonnie Marr
  • Bruce Searles
  • Edward Darling
چکیده

Recirculation during dual lumen veno-venous (DLVV) extracorporeal membrane oxygenation (ECMO) is a dynamic event that results in a fraction of the oxygenated blood exiting the arterial lumen and immediately shunting back into the venous lumen. Excessive recirculation will result in suboptimal oxygen delivery to the patient. Ultrasound dilution is a technology that has been shown to rapidly quantify recirculation in veno-venous (VV) ECMO animal models. This manuscript reports the first clinical application of ultrasound dilution in quantifying recirculation during neonatal VV ECMO. A 2.8-kg neonate with congenital diaphragmatic hernia was placed on VV ECMO using a single DLVV cannula inserted into the right atrium through the internal jugular vein. Ultrasound sensors were clamped to the arterial and venous lines near the dual lumen cannula and 3- to 5-mL bolus injections of isotonic saline were used proximal to the circuit heat exchanger to make the recirculation measurements. Recirculation measurements were made after initiation and periodically thereafter. During the 12-day ECMO period, 86 recirculation measurements were performed. The average recirculation was 34.3% (range, 15-57%). Reproducibility of paired measurements was 5.6%. Changes in patient positioning resulted in significant changes in recirculation. Measurements using platelet injections were compared with those made with saline. The two were found to closely correlate (mean difference, .25% +/- 2.8%). Ultrasound dilution measurements of recirculation provided rapid monitoring data during a clinical VV ECMO procedure. Application of this technique could provide early data that will assist the clinician in guiding interventions to minimize recirculation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Severe hypoxemia during veno-venous extracorporeal membrane oxygenation: exploring the limits of extracorporeal respiratory support

OBJECTIVE Veno-venous extracorporeal oxygenation for respiratory support has emerged as a rescue alternative for patients with hypoxemia. However, in some patients with more severe lung injury, extracorporeal support fails to restore arterial oxygenation. Based on four clinical vignettes, the aims of this article were to describe the pathophysiology of this concerning problem and to discuss pos...

متن کامل

Cannula Design and Recirculation During Venovenous Extracorporeal Membrane Oxygenation

Extracorporeal membrane oxygenation (ECMO) is used as a lifesaving rescue treatment in refractory respiratory or cardiac failure. During venovenous (VV) ECMO, the presence of recirculation is known, but quantification and actions to minimize recirculation after measurement are to date not routinely practiced. In the current study, we investigated the effect of draining cannula design on recircu...

متن کامل

Recirculation during veno-venous extra-corporeal membrane oxygenation--a simulation study.

PURPOSE Veno-venous ECMO is indicated in reversible life-threatening respiratory failure without life-threatening circulatory failure. Recirculation of oxygenated blood in the ECMO circuit decreases efficiency of patient oxygen delivery but is difficult to measure. We seek to identify and quantify some of the factors responsible for recirculation in a simulation model and compare with clinical ...

متن کامل

Recirculation Differences in Veno-Venous Extracorporeal Membrane Oxygenation By Different Types of Cannula Designs

Introduction Effectiveness of veno-venous (VV) ECMO treatment is in part dependent on the magnitude of recirculation. The recirculation fraction (RF) is for example influenced by cannulation type (dual lumen or single lumen cannulas), cannula position, pump flow, and cardiac output. RF might also be affected by cannula design. Knowledge of RF related to a certain cannula design might influence ...

متن کامل

A case of veno‐venous extracorporeal membrane oxygenation for severe respiratory failure in a superobese patient

After risk assessment, veno-venous extracorporeal membrane oxygenation (ECMO) has been achieved in a superobese adult patient as a bridge to recovery of respiratory failure, despite the weight-related difficulties. Early v-v ECMO implantation could be considered to support and to conduct weaning both from sedation and from invasive mechanical ventilation, with the goal to perform physiokinesith...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of extra-corporeal technology

دوره 40 3  شماره 

صفحات  -

تاریخ انتشار 2008