Estimation of error limits for cerebral blood flow values obtained from xenon-133 clearance curves.

نویسنده

  • E Ryding
چکیده

I provide the theoretical basis for an error calculus for measurements of cerebral blood flow using a freely diffusible tracer substance such as xenon-133. The use of the error calculus is exemplified by a study of the effect on the error margins in measurements of gray matter blood flow from flow level, relative weight of the gray matter compartment, and use of the earliest parts of the clearance curves. The clinical value of the error calculus is illustrated by its ability to separate different sources of measurement error. As a consequence, it is possible to optimize the method for blood flow calculation from the clearance curves, depending on the type of cerebral blood flow measurement. I show that if a true picture of the regional gray matter blood flow distribution is sought, the earliest part of the clearance curves should be used. This does, however, increase the error in the estimate of the average cerebral blood flow value.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cerebral circulation studies using inhaled 133-xenon and the gamma camera.

Cerebral Circulation Studies Using Inhaled 133-Xenon and the Gamma Camera • Inhaled 133-xenon was utilized in conjunction with the Anger gamma scintillation camera to evaluate cerebral circulation in 20 asymptomatic control subjects and in 41 patients with clinical cerebrovascular disease. Sequental cerebral scintiphotos thus obtained revealed focal areas of decreased activity in 2 of 19 contro...

متن کامل

Comparison of microsphere and Xenon-133 clearance method in measuring skeletal muscle and cerebral blood flow.

In this study, we compared the Xenon-133 (Xe) clearance method with the microsphere method in measurement of skeletal muscle and cerebral blood flow (CBF). Over a wide range of flows (1-47 ml/min x 100 g), we compared these two methods with direct measurements of venous outflow in the gracilis muscle. Regression equations relating the Xe (stochastic method) and microsphere measurements of flow ...

متن کامل

Regional cerebral blood flow estimated by 133-xenon inhalation.

A method is described for estimating the clearance rate and fractional blood flow of the fast (gray matter) compartment of the brain from the first ten minutes of 122 XE clearance curves, following a one-minute inhalation. Computer-simulated data were used to test the adequacy of the two-compartmental model employed, and to evaluate the stability of the parameters in the presence of random nois...

متن کامل

Determination of regional cerebral blood flow by inhalation of 133-Xenon.

A method for estimating regional cerebral blood flow is described in which tracer amounts of Xe are inhaled for 2 min and monitored extracranially over the next 45 to 60 min. A three-compartment model used to analyze the resulting clearance curves provided separate blood flows for "gray" and "white" matter, plus a decay constant for a slow third component, believed to arise from extracerebral t...

متن کامل

Spectrum Subtraction Technique for Minimizing Extracranial Influence on Cerebral Blood Flow Measurements by Xenon Inhalation

Estimates of regional cerebral blood flow (rCBF) by the Xe inhalation method are influenced by isotope contamination from slow clearing extracerebral tissues. Subtraction of x-ray (31 kev) from gamma-ray counts (81 kev) has been suggested as a means of yielding clearance curves that are relatively free of such contamination. In the present study, rCBF measurements based on the total Xe spectrum...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 20 2  شماره 

صفحات  -

تاریخ انتشار 1989