Technical variability of the Vivago® wrist-worn accelerometer.
نویسندگان
چکیده
The aim was to assess the technical variability of a new wrist-worn accelerometer under controlled conditions with a shaker device and during normal daily physical activities (PAs). In the first experiment, 10 wrist-worn accelerometers (Vivago(®) Wellness, Paris, France) were attached to the shaker device. Variability was tested at five shaking frequencies (1.1, 2.1, 3.1, 4.1, and 10 Hz) for 10 min at each frequency. In the second experiment, 21 participants wore wrist-worn accelerometers and performed six consecutive 10-min periods of activity at increasing levels of intensity from sedentary to vigorous. Results from the first experiment show a modest inter- and intra-instrument reliability at low frequencies and that reliability improved as frequency increased. The inter-instrument coefficient of variation (CV) was 2.6-18.3%. The intra-instrument CV was 4.1-23.2%. Variability was similar in the second experiment with a CV inversely related to PA intensity. The inter- and intra-instrument CV varied from 24.2% and 19.9% for sedentary activities to 3.7% and 4.3% for vigorous PA, respectively. Results suggest that reliability was higher at high intensities, corresponding to moderate and vigorous PA, intensities generally recommended for public health purposes.
منابع مشابه
Validation of the Vivago Wrist-Worn accelerometer in the assessment of physical activity
BACKGROUND Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. METHODS Twe...
متن کاملValidation of the Vivago
Background: Most accelerometers are worn around the waist (hip or lower back) to assess habitual physical activity. Wrist-worn accelerometers may be an alternative to the waist-worn monitors and may improve compliance in studies with prolonged wear. The aim of this study was to validate the Vivago ® Wrist-Worn Accelerometer at various intensities of physical activity (PA) in adults. Methods: Tw...
متن کاملNumber of Days Required to Estimate Habitual Activity Using Wrist-Worn GENEActiv Accelerometer: A Cross-Sectional Study
INTRODUCTION Objective methods like accelerometers are feasible for large studies and may quantify variability in day-to-day physical activity better than self-report. The variability between days suggests that day of the week cannot be ignored in the design and analysis of physical activity studies. The purpose of this paper is to investigate the optimal number of days needed to obtain reliabl...
متن کاملAccelerometer wear-site detection: When one site does not suit all, all of the time.
OBJECTIVES Choice of accelerometer wear-site may facilitate greater compliance in research studies. We aimed to test whether a simple method could automatically discriminate whether an accelerometer was worn on the hip or wrist from free-living data. DESIGN Cross-sectional. METHODS Twenty-two 10-12y old children wore a GENEActiv at the wrist and at the hip for 7-days. The angle between the ...
متن کاملSeparating Bedtime Rest from Activity Using Waist or Wrist-Worn Accelerometers in Youth
Recent interest in sedentary behavior and technological advances expanded use of watch-size accelerometers for continuous monitoring of physical activity (PA) over extended periods (e.g., 24 h/day for 1 week) in studies conducted in natural living environment. This approach necessitates the development of new methods separating bedtime rest and activity periods from the accelerometer recordings...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of sports sciences
دوره 32 19 شماره
صفحات -
تاریخ انتشار 2014