Cardiac output in pregnancy; correlation between Evans blue dye and blood pressure methods.

نویسندگان

  • C H HENDRICKS
  • E J QUILLIGAN
چکیده

Cardiac output estimations clone by the pulse pressure method were compared to those done simultaneously by the dye method in pregnancy, labor, and in the early puerperium. The subjects selected were young, healthy and without edema or clinical evidence of heart disease. A total of 30 determinations was carried out on 23 subjects. Agreement within 25 per cent of the dye method was attained in 90 per cent of the blood pressure method tests.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a new cuvette densitometer for determination of cardiac output.

Quantitation of cardiac output by the Stewart-Hamilton method will have extended usefulness if the accuracy of measuring the concentration of Evans blue dye in whole blood is established. Cardiac outputs by this method have been compared in dogs with outputs by the rotameter and the Tick method. The constant-flow photometer (Friedlich) was used initially, but certain difficulties in its use led...

متن کامل

The blood volumes of the primary and secondary circulatory system in the Atlantic cod Gadus morhua L, using plasma bound Evans Blue and compartmental analysis.

The volume of the primary (PCS) and secondary (SCS) circulatory system in the Atlantic cod Gadus morhua was determined using a modified dye dilution technique. Cod (N=10) were chronically cannulated in the second afferent branchial artery with PE-50 tubing. Evans Blue dye was bound to harvested fish plasma at a concentration of 1 mg dye ml(-1) plasma, and injected at a concentration of 1 mg kg(...

متن کامل

A comparison of direct and extraction methods for the determination of T-1824 (Evans blue) in plasma and serum.

The dye T-1824 (Evans Blue) has gained wide acceptance for determining plasma volume. Recently there has been a renewed interest in dye circulation studies for the measurement of cardiac output, central volume, cardiac shunts, and valvular regurgitation. The method of estimation most commonly used is spectrophotometric analysis of the dye-tinged plasma (or serum) compared with standard dye solu...

متن کامل

Value of Continuous Photoelectric Recording of Dye Curves in the Estimation of Cardiac Output

In order to test photoelectric recording of dye curves, simultaneous determinations of cardiac output were made in 48 patients with heart disease with the Fick and dye-dilution technics. The dye curves were recorded with a Colson densitometer following either intrathoracic or antecubital injection of dye. Both Evans blue and indoeyanine green dyes were employed. Satisfactory agreement was noted...

متن کامل

Primary hypertension refractory to triple drug treatment: a study on central and peripheral hemodynamics.

origin of left main coronary artery from anterior sinus of Valsalva with myocardial infarction. SUMMARY Cardiac output, plasma volume and regional hemodynamic factors involved in blood pressure regulation were investigated in hypertensive patients refractory to the combined treatment with diuretics, propranolol and hydralazine. The patients were compared to hypertensive patients, matched for se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation research

دوره 3 5  شماره 

صفحات  -

تاریخ انتشار 1955