Feasibility of proton chemical shift imaging with a stereotactic headframe.

نویسندگان

  • Hyun-Man Baik
  • Bo-Young Choe
  • Byung-Chul Son
  • Moon-Chan Kim
  • Euy-Neying Kim
  • Hyoung-Koo Lee
  • Tae-Suk Suh
چکیده

To prove feasibility of proton chemical shift imaging ((1)H CSI) during stereotactic procedure, authors performed (1)H CSI in combination with a stereotactic headframe and selected targets according to local metabolic information, evaluated the pathologic results. The (1)H CSI directed stereotactic biopsy was performed in four patients. (1)H CSI and conventional Gd-enhancement stereotactic MRI were performed simultaneously after the fitting of a stereotactic headframe. Focal areas of increased phosphocholine(Cho)/phosphocreatine(Cr) and Lactate/Cr ratios were selected as target sites in the stereotactic MR images. (1)H CSI is possible with the stereotactic headframe in place. Pathologic samples taken from areas of increased Cho/Cr ratios and decreased NAA/Cr ratios provided information upon increased cellularity, mitoses and cellular atypism, and facilitated diagnosis. Pathologic samples taken from areas of increased Lac/Cr ratio showed predominant feature of necrosis. (1)H CSI was feasible with the stereotactic headframe in place. The final pathologic results obtained were concordant with the local metabolic information from (1)H CSI. We believe that (1)H CSI-directed stereotactic biopsy has the potential to significantly improve the accuracy of stereotactic biopsy targeting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms and prevention of thermal injury from gamma radiosurgery headframes during 3T MR imaging

Magnetic resonance imaging (MRI) is regularly used for stereotactic imaging of Gamma Knife (GK) radiosurgery patients for GK treatment planning. MRI-induced thermal injuries have occurred and been reported for GK patients with attached metallic headframes. Depending on the specific MR imaging and headframe conditions, a skin injury from MRI-induced heating can potentially occur where the four h...

متن کامل

Feasibility assessment of in vitro chemoresponse assay on stereotactic biopsies of glioblastoma multiforms: a step towards personalized medicine

Objective(s):P In vitro chemosensitivity and resistance assays (CSRAs) are a promising tool for personalized treatment of glioblastoma multiform (GBM). These assays require a minimum of 1 to 2 g of tumor specimen for testing, but this amount is not always accessible. We aimed to assess the feasibility and validity of utilizing stereotactic biopsies of GBM in CSRAs. Materials and Methods: Single...

متن کامل

Feasibility of Proton Transmission-Beam Stereotactic Ablative Radiotherapy versus Photon Stereotactic Ablative Radiotherapy for Lung Tumors: A Dosimetric and Feasibility Study

Stereotactic ablative radiotherapy is being increasingly adopted in the treatment of lung tumors. The use of proton beam therapy can further reduce dose to normal structures. However, uncertainty exists in proton-based treatment plans, including range uncertainties, large sensitivity to position uncertainty, and calculation of dose deposition in heterogeneous areas. This study investigated the ...

متن کامل

Scalp nerve blockade reduces pain after headframe placement in radiosurgery: a double blind, randomized clinical trial.

BACKGROUND Patients undergoing stereotactic headframe placement for radiosurgery report that discomfort associated with the headframe often lasts for the duration of the treatment day (approximately 6 hours). We hypothesize that blockade of scalp nerves prior to headframe placement reduces the incidence of moderate to severe head pain during the entire treatment day. We describe a randomized, d...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 21 1  شماره 

صفحات  -

تاریخ انتشار 2003