Continuous-flow analysis for glucose in serum, with use of hexokinase and glucose-6-phosphate dehydrogenase co-immobilized in tubular form.

نویسندگان

  • L P León
  • D K Chu
  • L R Snyder
  • C Horváth
چکیده

Hexokinase and glucose-6-phosphate dehydrogenase, co-immobilized at the inner wall of plastic tubing, were used with continuous-flow analyzers to measure serum glucose. The performance of the enzyme-containing coils meets the hydraulic requirements of the continuous-flow instruments, and the average carryover does not exceed 2.2%. A glucose concentration change of 1 g/L yields a 0.08 change in absorbance. There is no significant deviation from linearity for glucose concentrations up to 5 g/L. The method is similar to the Reference Method proposed by the Food and Drug Administration, and results by the two methods agree and correlate well (r = 0.999). The operational stability of the enzyme tubes is sufficient to allow the analysis of at least 10 000 serum samples. We investigated in detail the effect of reagent concentrations and temperature on the performance of the enzyme coils, and the results shed light on the nature of the heterogeneous dual-enzymic reaction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Routine glucose determination in serum by use of an immobilized glucose dehydrogenase nylon-tube reactor.

We report a method for immobilizing glucose dehydrogenase on the inside surface of nylon tubes to produce an immobilized-enzyme nylon-tube reactor. The glucose dehydrogenase reactor is integrated into the flow system of a continuous-flow analyzer to facilitate routine analysis of serum glucose at 50 samples/h. We compared results with those by the reference hexokinase/glucose-6-phosphate dehydr...

متن کامل

Immobilized uricase for automated assay of uric acid in serum

The wide use of bound enzyme coils with hexokinase and glucose-6-phosphate dehydrogenase in automated analysis for serum-glucose assay [1, 2-] demonstrates the potential of open tubular heterogeneous enzyme reactors [3] in clinical analysis. Such reactors have also been prepared with other enzymes I-4, 5] and in this paper the authors describe a continuous-flow method for uric acid assay with i...

متن کامل

Evaluation of the co-immobilized hexokinase/glucose-6-phosphate dehydrogenase method for glucose, as adapted to the Technicon SMAC.

We assessed the analytical performance of the co-immobilized hexokinase (EC 2.7.1.1) and glucose-6-phosphate dehydrogenase (EC 1.1.1.49) method for D-glucose analysis on the Technicon SMAC. The enzyme-containing coils were usable for one month, or 12 000 tests. Bilirubin, hemoglobin, lipemia, creatinine, uric acid, citric acid, and ascorbic acid did not interfere. Results with this method were ...

متن کامل

Properties and uses of immobilized light-emitting enzyme systems from Beneckea harveyi.

Bacterial luciferase and NADH:FMN oxidoreductase have been immobilized onto arylamine glass beads. These immobilized enzymes can detect as little as 0.2 pmol of NADH per assay sample. Glucose-6-phosphate dehydrogenase has been co-immobilized with these enzymes, and with this system it is possible to quantitate 1 pmol of glucose 6-phosphate. By co-immobilizing a fourth enzyme, hexokinase, onto t...

متن کامل

Succinic Acid Monoethyl Ester and Metformin Regulates Carbohydrate Metabolic Enzymes and Improves Glycemic Control in Streptozotocin-Nicotinamide Induced Type2 Diabetic Rats

Objective. Succnic acid mono ethyl ester (EMS) was recently proposed as an insulinotropic agent for the treatment of non-insulin dependent diabetes mellitus. In the present study the effect of EMS and Metformin on the activities of carbohydrate metabolic enzymes in streptozotocinnicotinamide induced type 2 diabeteic model was investigated. Methods. EMS were injected intraperitonially at doses 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 1980