Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience.

نویسندگان

  • Jonathan Weinstock
  • Yousef H Bader
  • Martin S Maron
  • Ethan J Rowin
  • Mark S Link
چکیده

BACKGROUND The subcutaneous implantable cardioverter defibrillator (S-ICD) has been developed to avert risks associated with transvenous defibrillator leads. The technology is attractive for younger patients, such as those with hypertrophic cardiomyopathy (HCM). However, there are limited data on S-ICD use in HCM. METHODS AND RESULTS HCM patients identified at risk for sudden death were considered for S-ICD implantation. Patients were screened for potential oversensing by surface electrocardiography (ECG). At implant, defibrillation threshold (DFT) testing was performed at 65, 50, and 35 joules (J). Twenty-seven patients were considered for S-ICD implantation, and after screening, 23 (85%) remained eligible. The presence of a bundle branch block was associated with screening failure, whereas elevated body mass index (BMI) showed a trend toward association. One patient passed screening at rest, but failed with an ECG obtained after exercise. At implant, the S-ICD terminated ventricular fibrillation (VF) with a 65J shock in all 15 implanted patients and a 50J shock was successful in 12 of 15. A 35J shock terminated VF in 10 of 12 patients. DFT failure at 50 J was associated with a higher BMI. There were no appropriate shocks after a median follow-up of 17.5 (3-35) months, and 1 patient received an inappropriate shock attributable to a temporary reduction in QRS amplitude while bending forward, resulting in oversensing, despite successful screening. CONCLUSIONS In a high-risk HCM cohort without a pacing indication referred for consideration of an ICD, the majority were eligible for S-ICD. The S-ICD is effective at recognizing and terminating VF at implant with a wide safety margin.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Oversensing of atrial fibrillatory waves in a subcutaneous implantable cardioverter-defibrillator

Introduction Implantable cardioverter-defibrillators (ICDs) have been shown to improve survival in patients with ischemic or nonischemic cardiomyopathy when used for primary and secondary prevention settings. The limitations of transvenous ICDs include postimplant adverse events, defibrillator lead failure, and inappropriate shocks for atrial tachyarrhythmias due to fast ventricular response ra...

متن کامل

Subcutaneous Implantable Cardioverter Defibrillator: Early Experience

INTRODUCTION The implantable cardioverter defibrillator had been increasing the survival of patients at high risk for sudden cardiac death. The subcutaneous implantable cardioverter defibrillator was developed to mitigate the complications inherent to lead placement into cardiovascular system. OBJECTIVE To report the initial experience of 18 consecutive cases of subcutaneous implantable cardi...

متن کامل

Hypertrophic cardiomyopathy and sudden death: new perspectives on risk stratification and prevention with the implantable cardioverter-defibrillator.

Hypertrophic cardiomyopathy is a genetic cardiac disease with a particularly heterogeneous presentation and diverse natural history. Sudden and unexpected death has been recognized as a prominent and devastating consequence of hypertrophic cardiomyopathy since the initial description of this disease over 40 years ago. Many authors have emphasized that these catastrophic events occur not uncommo...

متن کامل

Surface fragmented QRS in a patient with hypertrophic cardiomyopathy and malignant arrhythmias: Is there an association?

An 18- year old woman with hypertrophic cardiomyopathy, aborted sudden cardiac death and implanted with an implantable cardioverter defibrillator (ICD), developed progressive fragmentation of her surface 12-lead electrocardiogram (ECG). During the follow-up, she presented with multiple appropriate ICD discharges. Here, we discuss the possible association between surface fragmented ECG and the r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Heart Association

دوره 5 2  شماره 

صفحات  -

تاریخ انتشار 2016