Chemo-affinity of titania for the column-switching HPLC analysis of phosphopeptides.

نویسندگان

  • Akira Sano
  • Hiroshi Nakamura
چکیده

A column-switching high-performance liquid chromatography (HPLC) system for the determination of phosphopeptides has been developed. The method is based on the selective adsorption of phosphopeptides on a titania (TiO2) precolumn and successive HPLC separation of the phosphopeptides on an anion-exchange column with a UV detector (215 nm). The recoveries of phosphopeptides were tested using authentic phosphopeptides [Gln-Ile-Ser(p)-Val-Arg, Ile-Ser(p)-Val-Arg and Lys-Gln-Ile-Ser(p)-Val-Arg] at an injection amount of 1 microg. The recoveries were 74.3, 79.6, and 82.6%, respectively, while the corresponding dephosphopeptides were not retained on the titania precolumn.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titania as a chemo-affinity support for the column-switching HPLC analysis of phosphopeptides: application to the characterization of phosphorylation sites in proteins by combination with protease digestion and electrospray ionization mass spectrometry.

A method for the determination of phosphorylation sites in phosphoproteins based on column-switching high-performance liquid chromatography (HPLC) has been developed. The HPLC system consisted of a titania precolumn for the selective adsorption of phosphopeptides, an anion-exchange analytical column and a UV detector (215 nm). Rabbit muscle phosphorylase a (RPa) and porcine stomach pepsin (PSP)...

متن کامل

Phosphopeptide-selective column-switching RP-HPLC with a titania precolumn.

A methodology of phosphopeptide-selective analysis coupled with column-switching HPLC utilizing titania as precolumn media is presented. Phosphopeptides were selectively enriched on titania packing within a protein/peptide mixture without any additional procedure, and analyzed by column-switching high-performance liquid chromatography. First, phospho-compounds were separated from complex mixtur...

متن کامل

Facilitating Phosphopeptide Analysis Using the Agilent HPLC Phosphochip

The analysis of phosphopeptides can be particularly challenging since they are mostly present at very low concentrations in a complex proteolytic sample. Selective enrichment strategies have been introduced to capture phosphopeptides from the sample prior to MS analysis, which can enhance detection capabilities. One of the more successful phosphopeptide enrichment techniques is based on the sel...

متن کامل

Selective enrichment of glycopeptides/phosphopeptides using porous titania microspheres.

Titanium dioxide (TiO(2)) microspheres synthesized by sol-gel method showed high affinity to glycopeptides and were successfully used for simultaneous enrichment of glycopeptides and phosphopeptides.

متن کامل

Selective Extraction and Determination of Di(2-ethylhexyl) Phthalate in Aqueous Solution by HPLC Coupled with Molecularly Imprinted Solid-phase Extraction

Surface Molecularly Imprinted Polymer (SMIP) for selective adsorption of di(2-ethylhexyl) phthalate(DEHP) was prepared on the surface of silica gel which was modified by aminopropyltriethoxysilane and acryloyl chloride in a two-step method. The prepared SMIP was used to prepare Molecularly Imprinted Solid-Phase Extraction (MISPE) column for selective extraction of DEHP from aqueous solution...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2004