Assessment of thrombus in acute middle cerebral artery occlusion using thin-slice nonenhanced Computed Tomography reconstructions.

نویسندگان

  • Christian H Riedel
  • Ulf Jensen
  • Axel Rohr
  • Marc Tietke
  • Karsten Alfke
  • Stephan Ulmer
  • Olav Jansen
چکیده

BACKGROUND AND PURPOSE We sought to evaluate how accurately length and volume of thrombotic clots occluding cerebral arteries of patients with acute ischemic stroke can be assessed from nonenhanced CT (NECT) scans reconstructed with different slice widths. METHODS NECT image data of 58 patients with acute ischemic stroke with vascular occlusion proven by CT angiography were reconstructed with slice widths of 1.25 mm, 2.5 mm, 3.75 mm, and 5 mm. Thrombus lengths and volumes were quantified based on these NECT images by detecting and segmenting intra-arterial hyperdensities. The results were compared with reference values of thrombus length and volume obtained from CT angiography images using Bland-Altman analysis and predefined levels or tolerance to find NECT slice thicknesses that allow for sufficiently accurate thrombus quantification. RESULTS Thrombus length can be measured with high accuracy using the hyperdense middle cerebral artery sign detected in NECT images with slice thicknesses of 1.25 mm and 2.5 mm. We found mean deviations from the reference values and limits of agreement of -0.1 mm+/-0.6 mm with slice widths of 1.25 mm and 0.1 mm+/-0.7 mm for slice widths of 2.5 mm. Thrombus length measurements in NECT images with higher slice width and all evaluated thrombus volume measurements exhibited severe dependence on the level and did not match the accuracy criteria. CONCLUSIONS The length of the hyperdense middle cerebral artery sign as detected on thin-slice NECT reconstructions in patients with acute ischemic stroke can be used to quantify thrombotic burden accurately. Thus, it might qualify as a new diagnostic parameter in acute stroke management that indicates and quantifies the extent of vascular obliteration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thin-slice reconstructions of nonenhanced CT images allow for detection of thrombus in acute stroke.

BACKGROUND AND PURPOSE The purpose of this study was to investigate whether thin-slice image reconstructions of cranial nonenhanced CT scans could be used to significantly increase sensitivity for detecting intraluminal thrombus in patients with acute ischemic stroke due to proximal occlusion of the middle cerebral artery. METHODS In a prospective case series, the raw data of nonenhanced CT s...

متن کامل

The importance of size: successful recanalization by intravenous thrombolysis in acute anterior stroke depends on thrombus length.

BACKGROUND AND PURPOSE We hypothesize that in acute middle cerebral artery stroke, thrombus lengths measured in thin-slice nonenhanced CT images define a limit beyond which systemic thrombolysis will fail to recanalize occluded arteries. METHODS In 138 patients who presented with acute middle cerebral artery stroke and who were treated with intravenous thrombolysis (IVT), we measured lengths ...

متن کامل

Detection of thrombus in acute ischemic stroke: value of thin-section noncontrast-computed tomography.

BACKGROUND AND PURPOSE Previous studies on the hyperdense middle cerebral artery (MCA) sign were conducted using > or =5-mm thickness noncontrast-computed tomography (NCT). The purpose of this study was to compare thin-section NCT with 5-mm NCT in the detection of thrombus in acute ischemic stroke. METHODS Enrolled were consecutive 51 patients with acute infarction in the anterior or MCA terr...

متن کامل

Angiographic reconstructions from whole-brain perfusion CT for the detection of large vessel occlusion in acute stroke.

BACKGROUND AND PURPOSE Multimodal CT imaging consisting of nonenhanced CT, CT angiography (CTA), and whole-brain volume perfusion CT is increasingly used for acute stroke imaging. In these patients, presence of vessel occlusion is an important factor governing treatment decisions and possible endovascular therapy. The goal of this study was to assess the value and diagnostic accuracy of angiogr...

متن کامل

Response to letter regarding article, "Clot length distribution and predictors in anterior circulation stroke: implications for intra-arterial therapy".

BACKGROUND AND PURPOSE Thin-section noncontrast computed tomography images can be used to measure hyperdense clot length in acute ischemic stroke. Clots≥8 mm have a very low probability of intravenous tissue-type plasminogen activator recanalization and hence may benefit from a bridging intra-arterial approach. To understand the prevalence of such clots, we sought to determine the distribution ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Stroke

دوره 41 8  شماره 

صفحات  -

تاریخ انتشار 2010