Complex Impedance as a Diagnostic Tool for Characterizing Thermal Detectors

نویسنده

  • John E. Vaillancourt
چکیده

The complex ac impedance of a bolometer or microcalorimeter detector is easily measured and can be used to determine thermal time constants, thermal resistances, heat capacities, and sensitivities. Accurately extracting this information requires an understanding of the electrical and thermal properties of both the detector and the measurement system. We show that this is a practical method for measuring parameters in detectors with moderately complex thermal systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two Models for Bolometer and Microcalorimeter Detectors with Complex Thermal Architectures

We have developed two analytical models to describe the performance of cryogenic microcalorimeters and bolometers. One of the models is suitable to describe Transition Edge Sensor(TES) detectors with an integrated absorber, the other is suitable for detectors with large absorbers. Both models take into account hotelectron decoupling and absorber decoupling. The differential equations describing...

متن کامل

Complex Impedance and Equivalent Bolometer Analysis of a Low Noise Bolometer for SAFARI

Transition-edge-sensor (TES) bolometers are the chosen detector technology for the SAFARI Imaging Spectrometer on the SPICA telescope. For this mission, SRON is developing bolometers, each consisting of a TiAu TES that is weakly coupled to the thermal bath through thin legs of silicon nitride. In order to understand and optimize the bolometer and to verify our detector models, we characterize t...

متن کامل

Optimization of a bolometer detector for ITER based on Pt absorber on SiN membrane.

Any plasma diagnostic in ITER must be able to operate at temperatures in excess of 200 °C and neutron loads corresponding to 0.1 dpa over its lifetime. To achieve this aim for the bolometer diagnostic, a miniaturized metal resistor bolometer detector based on Pt absorbers galvanically deposited on SiN membranes is being developed. The first two generations of detectors featured up to 4.5 μm thi...

متن کامل

Characterizing films of polyethylene blends: An application of colorimetric parameters measurements

This study reports an application of instrumental color measurement for quantifying and comparing the optical properties of high density polyethylene HDPE and low density polyethylene LDPE blend films and the effect of blending ratio and miscibility on these properties. The technique of spectrophotometry in transmission and reflectance modes can be used as a versatile tool to evaluate the color...

متن کامل

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005