Advanced reconstruction of attenuation maps using SPECT emission data only

نویسندگان

  • André Salomon
  • Andreas Goedicke
  • Til Aach
چکیده

Today, attenuation corrected SPECT, typically performed using CT or Gadolinium line source based transmission scans, is more and more becoming standard in many medical applications. Moreover, the information about the material density distribution provided by these scans is key for other artifact compensation approaches in advanced SPECT reconstruction. Major drawbacks of these approaches are the additional patient radiation and hardware/maintenance costs as well as the additional workflow effort, e.g. if the CT scans are not performed on a hybrid scanner. It has been investigated in the past, whether it is possible to recover this structural information solely from the SPECT scan data. However, the investigated methods often result in noticeable image artifacts due to cross-dependences between attenuation and activity distribution estimation. With the simultaneous reconstruction method presented in this paper, we aim to effectively prevent these typical cross-talk artifacts using a-priori known atlas information of a human body. At first, an initial 3D shape model is coarsely registered to the SPECT data using anatomical landmarks and each organ structure within the model is identified with its typical attenuation coefficient. During the iterative reconstruction based on a modified ML-EM scheme, the algorithm simultaneously adapts both, the local activity estimation and the 3D shape model in order to improve the overall consistency between measured and estimated sinogram data. By explicitly avoiding topology modifications resulting in a non-anatomical state, we ensure that the estimated attenuation map remains realistic. Several tests with simulated as well as real patient SPECT data were performed to test the proposed algorithm, which demonstrated reliable convergence behaviour in both cases. Comparing the achieved results with available reference data, an overall good agreement for both cold as well as hot activity regions could be observed (mean deviation: -5.98%).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonlinear Dual Reconstruction of SPECT Activity and Attenuation Images

In single photon emission computed tomography (SPECT), accurate attenuation maps are needed to perform essential attenuation compensation for high quality radioactivity estimation. Formulating the SPECT activity and attenuation reconstruction tasks as coupled signal estimation and system parameter identification problems, where the activity distribution and the attenuation parameter are treated...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

A model based, anatomy dependent method for ultra-fast creation of primary SPECT projections

  Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...

متن کامل

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009