Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.
نویسنده
چکیده
Cardiac output measured by thermodilution in 25 patients within 24 hours of acute myocardial infarction was compared with cardiac output measured by Doppler echocardiography (24 patients) and electrical bioimpedance (25 patients). The mean (range) cardiac outputs measured by Doppler (4.03 (2.2-6.0) 1/min) and electrical bioimpedance (3.79 (1.1-6.2) 1/min) were similar to the mean thermodilution value (3.95 (2.1-6.2) 1/min). Both non-invasive techniques agreed closely with thermodilution in most patients. None the less, three results with each method disagreed with thermodilution by more than 1 1/min. Both non-invasive techniques were reproducible and accurate in most patients with acute myocardial infarction. Doppler echocardiography was time consuming and technically demanding. Electrical bioimpedance was simple to use and had the additional advantage of allowing continuous monitoring of the cardiac output.
منابع مشابه
Non-invasive measurement of cardiac output by whole-body bio-impedance during dobutamine stress echocardiography: clinical implications in patients with left ventricular dysfunction and ischaemia.
OBJECTIVES To compare non-invasive determination of cardiac index (CI) by whole body electrical bioimpedance using the NICaS apparatus and Doppler echocardiography, and the role of cardiac power index (Cpi) and total peripheral resistance index (TPRi) calculation during dobutamine stress echocardiography (DSE). SUBJECTS AND METHODS We enrolled 60 consecutive patients undergoing DSE. Patients ...
متن کاملNon-invasive estimation of cardiac wall stress by using tissue doppler-echocardiography ultrasound images: People with coronary artery stenosis
In this study, a method for non-invasive estimation of stress on the heart wall in the diastole phase is presented using ultrasound echocardiography and tissue Doppler imaging. The aim of this study was to evaluate the stress on the heart wall as a pre-diagnosis to identify people with coronary artery stenosis. 29 patients with stenosis of more than 70%, 30 patients with stenosis of 50 to 7...
متن کاملComparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac outputy
Background. Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophagea...
متن کاملSimultaneous measurement of cardiac output by thermodilution, thoracic electrical bioimpedance and Doppler ultrasound.
To evaluate the accuracy of two non-invasive techniques for cardiac output (CO) measurement, we have measured CO simultaneously by thoracic electrical bioimpedance (TEB), pulsed Doppler ultrasound (DU) and standard thermodilution methods (TD) under different clinical conditions. Measurements were made in 10 patients: (I) during steady state anaesthesia with controlled IPPV ventilation (n = 131)...
متن کاملComparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.
BACKGROUND Impedance cardiography (ICG) has been used extensively to estimate stroke volume (SV) and cardiac output (CO) from changes of thoracic electrical bioimpedance (TEB). However, studies comparing ICG with reference methods have questioned the reliability of this approach. Electrical velocimetry (EV) provides a new algorithm to calculate CO from variations in TEB. As the transoesophageal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- British heart journal
دوره 63 2 شماره
صفحات -
تاریخ انتشار 1990