Roentgen stereophotogrammetric analysis methods for determining ten causes of lengthening of a soft-tissue anterior cruciate ligament graft construct.

نویسندگان

  • Conrad Smith
  • M L Hull
  • S M Howell
چکیده

There are many causes of lengthening of an anterior cruciate ligament soft-tissue graft construct (i.e., graft+fixation devices+bone), which can lead to an increase in anterior laxity. These causes can be due to plastic deformation andor an increase in elastic deformation. The purposes of this in vitro study were (1) to develop the methods to quantify eight causes (four elastic and four plastic) associated with the tibial and femoral fixations using Roentgen stereophotogrammetric analysis (RSA) and to demonstrate the usefulness of these methods, (2) to assess how well an empirical relationship between an increase in length of the graft construct and an increase in anterior laxity predicts two causes (one elastic and one plastic) associated with the graft midsubstance, and (3) to determine the increase in anterior tare laxity (i.e., laxity under the application of a 30 N anterior tare force) before the graft force reaches zero. Markers were injected into the tibia, femur, and graft in six cadaveric legs whose knees were reconstructed with single-loop tibialis grafts. To satisfy the first objective, legs were subjected to 1500 cycles at 14 Hz of 150 N anterior force transmitted at the knee. Based on marker 3D coordinates, equations were developed for determining eight causes associated with the fixations. After 1500 load cycles, plastic deformation between the graft and WasherLoc tibial fixation was the greatest cause with an average of 0.8+/-0.5 mm followed by plastic deformation between the graft and cross-pin-type femoral fixation with an average of 0.5+/-0.1 mm. The elastic deformations between the graft and tibial fixation and between the graft and femoral fixation decreased averages of 0.3+/-0.3 mm and 0.2+/-0.1 mm, respectively. The remaining four causes associated with the fixations were close to 0. To satisfy the remaining two objectives, after cyclic loading, the graft was lengthened incrementally while the 30 N anterior tare laxity, 150 N anterior laxity, and graft tension were measured. The one plastic cause and one elastic cause associated with the graft midsubstance were predicted by the empirical relationships with random errors (i.e., precision) of 0.9 mm and 0.5 mm, respectively. The minimum increase in 30 N anterior tare laxity before the graft force reached zero was 5 mm. Hence, each of the eight causes of an increase in the 150 N anterior laxity associated with the fixations can be determined with RSA as long as the overall increase in the 30 N anterior tare laxity does not exceed 5 mm. However, predicting the two causes associated with the graft using empirical relationships is prone to large errors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lengthening of a single-loop tibialis tendon graft construct after cyclic loading: a study using Roentgen stereophotogrammetric analysis.

Although single-loop tibialis tendon allografts have increased in popularity owing to their many advantages over patellar tendon and double-loop hamstring tendon autografts, some percentage of the patient population do not have clinically stable knees following anterior cruciate ligament reconstruction with single-loop tibialis tendon allografts. Therefore, it would be advantageous to determine...

متن کامل

Does graft construct lengthening at the fixations cause an increase in anterior laxity following anterior cruciate ligament reconstruction in vivo?

A millimeter-for-millimeter relation between an increase in length of an anterior cruciate ligament graft construct and an increase in anterior laxity has been demonstrated in multiple in vitro studies. Based on this relation, a 3 mm increase in length of the graft construct following surgery could manifest as a 3 mm increase in anterior laxity in vivo, which is considered clinically unstable. ...

متن کامل

Migration of radio-opaque markers injected into tendon grafts: a study using roentgen stereophotogrammetric analysis (RSA).

An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct either at the sites of fixation and/or between the sites of fixation (i.e., graft substance). Roentgen stereophotogrammetric analysis (RSA), which requires that radio-opaque markers be attached to the graft, has been shown to be a useful technique in...

متن کامل

Lengthening of double-looped tendon graft constructs in three regions after cyclic loading: a study using Roentgen stereophotogrammetric analysis.

Lengthening of a double-looped tendon graft construct used to reconstruct the anterior cruciate ligament (ACL) can result in an increase in anterior knee laxity and affect the stability of the reconstructed knee. Three possible regions where lengthening of the construct can occur are (1) the region of the tibial fixation, (2) the region of the femoral fixation, and (3) the region of the graft b...

متن کامل

How cyclic loading affects the migration of radio-opaque markers attached to tendon grafts using a new method: a study using roentgen stereophotogrammetric analysis (RSA).

An increase in anterior laxity following reconstruction of the anterior cruciate ligament (ACL) can result from lengthening of the graft construct in either the regions of fixation and/or the region of the graft substance between the fixations. RSA could be a useful technique to determine lengthening in these regions if a method can be devised for attaching radio-opaque markers to soft tissue g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 130 4  شماره 

صفحات  -

تاریخ انتشار 2008