AC Electroosmosis-Enhanced Nanoplasmofluidic Detection of Ultralow-Concentration Cytokine.
نویسندگان
چکیده
Label-free, nanoparticle-based plasmonic optical biosensing, combined with device miniaturization and microarray integration, has emerged as a promising approach for rapid, multiplexed biomolecular analysis. However, limited sensitivity prevents the wide use of such integrated label-free nanoplasmonic biosensors in clinical and life science applications where low-abundance biomolecule detection is needed. Here, we present a nanoplasmofluidic device integrated with microelectrodes for rapid, label-free analysis of a low-abundance cell signaling protein, detected by AC electroosmosis-enhanced localized surface plasmon resonance (ACE-LSPR) biofunctional nanoparticle imaging. The ACE-LSPR device is constructed using both bottom-up and top-down sensor fabrication methods, allowing the seamless integration of antibody-conjugated gold nanorod (AuNR) biosensor arrays with microelectrodes on the same microfluidic platform. Applying an AC voltage to microelectrodes while scanning the scattering light intensity variation of the AuNR biosensors results in significantly enhanced biosensing performance. The AC electroosmosis (ACEO) based enhancement of the biosensor performance enables rapid (5-15 min) quantification of IL-1β, a pro-inflammatory cytokine biomarker, with a sensitivity down to 158.5 fg/mL (9.1 fM) for spiked samples in PBS and 1 pg/mL (58 fM) for diluted human serum. Together with the optimized detection sensitivity and speed, our study presents the first critical step toward the application of nanoplasmonic biosensing technology to immune status monitoring guided by low-abundance cytokine measurement.
منابع مشابه
Particle detection by electrical impedance spectroscopy with asymmetric-polarization AC electroosmotic trapping
Recently, considerable interest and effort have been devoted to the on-site detection of low-concentration pathogenic bacteria in order to deter infectious diseases and bioterrorism. Conventionally, bacteria detection involves culturing, which is time-consuming and unfeasible under field conditions. Microfluidic devices with integrated electrical detection will enable fast, low-cost, and portab...
متن کاملA Simple Method to Integrate In Situ Nano-Particle Focusing With Cantilever Detection
Real-time detection of low-concentration pathogenic/ toxic bioparticles is important for deterring infectious diseases and bioterrorism, which is difficult to achieve for lab-on-a-chip. Currently, sensitivity is achieved through time-consuming culturing or sophisticated processing, often unfeasible under field conditions. Real-time particle enrichment will improve sensor capability. This paper ...
متن کاملImproved Protein Binding Rate for Bio- Sensors Using Ac Electroosmosis
Many biosensors are limited by long detection times that result from transport limitations of large macromolecules such as proteins which must reach the active surface in order to be detected. To overcome this difficulty, a common biosensor, the quartz crystal microbalance was modified with a microelectrode pattern capable of producing AC electroosmosis. The mixing pattern that is thereby gener...
متن کاملAn electrostatic micromechanical biosensor for electrical detection of label- free DNA
Related Articles Development of a microbial high-throughput screening instrument based on elastic light scatter patterns Rev. Sci. Instrum. 83, 044304 (2012) Improved delay-leaping simulation algorithm for biochemical reaction systems with delays JCP: BioChem. Phys. 6, 04B609 (2012) Improved delay-leaping simulation algorithm for biochemical reaction systems with delays J. Chem. Phys. 136, 1441...
متن کاملExperimental Study of Electrolyte Dependence of Ac Electroosmotic Pumps
Recent studies indicate increased efficiency of microfluidic ac electro-osmotic pumps by utilizing broken symmetries with raised steps on the electrodes. An experimental study on the dependence of ac electroosmosis in microchannels on solution chemistry for the new fast aceo stepped pumps is reported. Micro PIV was used to determine peak velocities for M mM ! " concentrations of KCl, NaCl, CaCl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nano letters
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2017