Mechanical behaviors of Flutter VRP1, Shaker, and Acapella devices.

نویسندگان

  • Alexandre Pereira dos Santos
  • Rogério Contato Guimarães
  • Eliane Maria de Carvalho
  • Ada Clarice Gastaldi
چکیده

BACKGROUND Flutter VRP1, Shaker, and Acapella are devices that combine positive expiratory pressure (PEP) and oscillations. OBJECTIVES To compare the mechanical performance of the Flutter VRP1, Shaker, and Acapella devices. METHODS An experimental platform and a ventilator, used a flow generator at 5, 10, 15, 20, 26, and 32 L/min, were employed at angles of -30°, 0°, and +30° to evaluate Flutter VRP1 and Shaker, whereas Acapella was adjusted at intermediate, higher, and lower levels of resistance, including positive expiratory pressures (PEP) along with air outflow rates and oscillation frequencies. RESULTS When the relationships between pressure amplitudes of all air flows were analyzed for the 3 devices at low and intermediate pressures levels, no statistically significant differences were observed in mean pressure amplitudes between Flutter VRP1 and Shaker devices. However, both devices had different values from Acapella, with their pressure amplitude values being higher than that of Acapella (P = .04). There were no statistically significant differences in PEP for the 3 angles or marks regarding all air flows. The expected relationships between variables were observed, with increases in PEP, compared to those of air flows and resistance. Nevertheless, there was a statistically significant difference in frequency of oscillation between these devices and Acapella, whose value was higher than those of Flutter VRP1 and Shaker devices (P = .002). At intermediate pressure levels, the patterns were the same, in comparison to low pressures, although the Acapella device showed frequencies of oscillation values lower than those of Flutter VRP1 and Shaker (P < .001). At high pressures, there were no statistically significant differences among the 3 devices for frequency of oscillations. CONCLUSIONS The Flutter VRP1 and Shaker devices had a similar performance to that of Acapella in many aspects, except for PEP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance comparison of two oscillating positive expiratory pressure devices: Acapella versus Flutter.

BACKGROUND Oscillatory positive expiratory pressure (PEP) with the Flutter device facilitates secretion removal. In the Flutter a steel ball vibrates inside a cone, causing air flow vibration. A new device, the Acapella, uses a counterweighted plug and magnet to create air flow oscillation. The Acapella comes in 2 models: one for patients with expiratory flow > or = 15 L/min and one for < or = ...

متن کامل

Effects of ELTGOL and Flutter VRP1® on the dynamic and static pulmonary volumes and on the secretion clearance of patients with bronchiectasis.

BACKGROUND Although respiratory physical therapy is considered fundamental in the treatment of hypersecretive patients, there is little evidence of its physiological and therapeutic effects in bronchiectasis patients. OBJECTIVE To evaluate the acute physiological effects of ELTGOL and Flutter VRP1® in dynamic and static lung volumes in patients with bronchiectasis and, secondarily, to study t...

متن کامل

Mechanical evaluation of a respiratory device.

This article aims to characterize the mechanical behaviour of the Flutter VRP1, a respiratory physiotherapy device designed to aid sputum clearance of the airways of patients. The device resembles a smoking pipe with a conical cavity containing a stainless steel sphere which floats up and down while the patient comes with a forced expiration through it. The sphere's oscillatory movement is func...

متن کامل

Physiological effects of vibration in subjects with cystic fibrosis.

The physiological mechanisms by which vibration and other physiotherapy interventions may clear secretions in subjects with cystic fibrosis are unknown. The main aim of this study was to compare the expiratory flow rates and frequencies of airflow oscillation of vibration to those of Acapella(R), Flutter(R), positive expiratory pressure and percussion. Respiratory flow rates were measured durin...

متن کامل

Laboratory evaluation of four different devices for secretion mobilization: Acapella choice, green and blue versus water bottle.

BACKGROUND Secretion removal is a key issue in patients with respiratory diseases, and is known to be most effective at vibration frequencies of ∼ 13 Hz and with the greatest amplitudes possible. The Acapella devices and the water bottle are used for secretion removal in daily clinical practice but without detailed knowledge on optimal settings. The aim of this study was to evaluate the 3 diffe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 58 2  شماره 

صفحات  -

تاریخ انتشار 2013