Evaluation of intermediate coronary stenoses in acute coronary syndromes using pressure guidewire
نویسندگان
چکیده
Fractional flow reserve (FFR) is increasingly used to guide myocardial revascularisation. However, supporting evidence regarding its use originates from studies that have enrolled mainly patients with stable angina, while patients with acute coronary syndromes (ACS) have not been included. Notably, multifactorial microvascular dysfunction and an increased sympathetic tone in patients with ACS may lead to blunted response to adenosine and false-negative results of FFR due to submaximal hyperaemia. This may raise the possibility of deferring treatment of stenosis that instead would have needed dilatation, thus leaving a residual risk of preventable cardiac events. In this literature review, we aim at summarising laboratory and clinical investigations concerning the use of FFR in culprit and non-culprit lesions in ACS. Furthermore, we will report recent data on instantaneous wave-free ratio, an adenosine-free index of functional stenosis severity, in stable coronary artery disease and in patients with ACS.
منابع مشابه
Hemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study
BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...
متن کاملGuidewire flow obstruction effect on pressure drop-flow relationship in moderate coronary artery stenosis.
To evaluate the local hemodynamic effects of coronary artery balloon angioplasty, computational fluid dynamics was applied to representative stenoses geometry post-angioplasty (minimal lesion diameter d(m) = 1.8mm which produced 64% mean area stenoses) based on a group of patients and measured values of coronary flow reserve (CFR) returning to a normal range (3.6+/-0.3). The computations were a...
متن کاملCharacterizing momentum change and viscous loss of a hemodynamic endpoint in assessment of coronary lesions.
Myocardial fractional flow reserve (FFR(myo)) and coronary flow reserve (CFR), measured with guidewire, and quantitative angiography (QA) are widely used in combination to distinguish ischemic from non-ischemic coronary stenoses. Recent studies have shown that simultaneous measurements of FFR(myo) and CFR are recommended to dissociate conduit epicardial coronary stenoses from distal resistance ...
متن کاملThe diastolic flow-pressure gradient relation in coronary stenoses in humans.
OBJECTIVES We assessed the feasibility and reproducibility of the instantaneous diastolic coronary flow velocity-pressure gradient relation to characterize different degrees of coronary stenoses. BACKGROUND Assessment of the hemodynamic significance of coronary stenoses can be difficult. Using sensor-tipped guidewires, various physiologic indexes can be determined in the catheterization labor...
متن کاملEffects of diagnostic guidewire catheter presence on translesional hemodynamic measurements across significant coronary artery stenoses.
This study gains insight on the nature of flow blockage effects of small guidewire catheter sensors in measuring mean trans-stenotic pressure gradients Deltap across significant coronary artery stenoses. Detailed pulsatile hemodynamic computations were made in conjunction with previously reported clinical data in a group of patients with clinically significant coronary lesions before angioplast...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2017