Noise correction for HARDI and HYDI data obtained with multi-channel coils and sum of squares reconstruction: an anisotropic extension of the LMMSE.

نویسندگان

  • Véronique Brion
  • Cyril Poupon
  • Olivier Riff
  • Santiago Aja-Fernández
  • Antonio Tristán-Vega
  • Jean-François Mangin
  • Denis Le Bihan
  • Fabrice Poupon
چکیده

Parallel magnetic resonance imaging (MRI) yields noisy magnitude data, described in most cases as following a noncentral χ distribution when the signals received by the coils are combined as the sum of their squares. One well-known case of this noncentral χ noise model is the Rician model, but it is only valid in the case of single-channel acquisition. Although the use of parallel MRI is increasingly common, most of the correction methods still perform Rician noise removal, yielding an erroneous result due to an incorrect noise model. Moreover, the existence of noise correlations in phased array systems renders noise nonstationary and further modifies the noise description in parallel MRI. However, the noncentral χ model has been demonstrated to work as a good approximation as long as effective voxelwise parameters are used. A good correction step, adapted to the right noise model, is of paramount importance, especially when working with diffusion-weighted MR data, whose signal-to-noise ratio is low. In this paper, we present a noise removal technique designed to be fast enough for integration into a real-time reconstruction system, thus offering the convenience of obtaining corrected data almost instantaneously during the MRI scan. Our method employs the noncentral χ noise model and uses a simplified method to account for noise correlations; this leads to an efficient and rapid correction. The method consists of an anisotropic extension of the Linear Minimum Mean Square Error estimator (LMMSE) that is a far better edge-preserving method than the traditional LMMSE and addresses noncentral χ distributions along with empirically computed global effective parameters. The results on simulated and real data demonstrate that this anisotropic extended LMMSE outperforms the original LMMSE on images corrupted by noncentral χ noise. Moreover, in comparison with the existing LMMSE technique incorporating the estimation of voxelwise effective parameters, our method yields improved results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modelling Temporal Stability of EPI Time Series Using Magnitude Images Acquired with Multi-Channel Receiver Coils

In 2001, Krueger and Glover introduced a model describing the temporal SNR (tSNR) of an EPI time series as a function of image SNR (SNR(0)). This model has been used to study physiological noise in fMRI, to optimize fMRI acquisition parameters, and to estimate maximum attainable tSNR for a given set of MR image acquisition and processing parameters. In its current form, this noise model require...

متن کامل

7T multi-shell hybrid diffusion imaging (HYDI) for mapping brain connectivity in mice

Diffusion weighted imaging (DWI) is widely used to study microstructural characteristics of the brain. High angular resolution diffusion imaging (HARDI) samples diffusivity at a large number of spherical angles, to better resolve neural fibers that mix or cross. Here, we implemented a framework for advanced mathematical analysis of mouse 5-shell HARDI (b=1000, 3000, 4000, 8000, 12000 s/mm2), al...

متن کامل

Coil Combination Method for Multiple-Echo Sequences and PSF Mapping

INTRODUCTION: Phased array coils are increasingly used in MRI for improving the signal-to-noise ratio (SNR) or accelerating MRI acquisitions. Most image reconstruction approaches require a separate step to combine the data from the individual channels into a single composite image. Sum-ofsquares technique is widely used, but it is unsuitable when the phase information needs to be preserved. Opt...

متن کامل

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

Reconstruction of major fibers using 7T multi-shell Hybrid Diffusion Imaging in mice

Diffusion weighted imaging (DWI) can reveal the orientation of the underlying fiber populations in the brain. High angular resolution diffusion imaging (HARDI) is increasingly used to better resolve the orientation and mixing of fibers. Here, we assessed the added value of multi-shell q-space sampling on the reconstruction of major fibers using mathematical frameworks from q-ball imaging (QBI) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance imaging

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2013