A Comparison of Carbon Dioxide Elimination Measurements Between a Portable Indirect Calorimeter and Volumetric Capnography Monitor: An In Vitro Simulation.

نویسندگان

  • Craig D Smallwood
  • Enid E Martinez
  • Nilesh M Mehta
چکیده

BACKGROUND Gas exchange measurements for carbon dioxide elimination (V̇CO2 ) and oxygen consumption (V̇O2 ) have been used to derive resting energy expenditure and guide energy prescription. Volumetric capnography is used in intensive care units and provides V̇CO2 measurements that could be used for titrating respiratory and nutritional support. We have recently suggested that measuring V̇CO2 may be sufficient to obtain a reasonable estimate of energy expenditure. However, data describing the accuracy of gas exchange measurement devices are limited. METHODS We used an in vitro simulation model to test the accuracy of gas exchange measurements by 2 devices: the CCM Express indirect calorimeter and the NM3, a volumetric capnography monitor. A Huszczuk gas injection system combined with a high-fidelity lung simulator was used to simulate V̇O2 and V̇CO2 values in the pediatric and adult range. Bland-Altman analysis was used to examine the agreement between the measured and simulated values across a range of tidal volumes and gas exchange values. Additionally, agreement between the 2 devices was examined. RESULTS During the adult simulation with the CCM Express, the mean bias (95% CI) for V̇CO2 values was -12.6% (-16.4 to -8.8%) and -17.5% (-19.9 to -15.1%) for V̇O2 values. For the pediatric simulation with the CCM Express, mean bias for V̇O2 was -14.7% (-16.4 to -13.0%) and V̇CO2 was -10.9% (-13.5 to -8.3%). For the adult and pediatric simulations with the NM3, the bias for V̇CO2 was -8.2% (-15.7 to -0.7%) and -8.3% (-19.4 to -2.8%), respectively. Between the 2 devices, the mean bias was -4.4% (-10.2 to 1.3%) and -2.3% (-11.4 to 6.8%) for the adult and pediatric V̇CO2 simulations, respectively. CONCLUSIONS Currently available portable gas exchange monitors demonstrated acceptable agreement with reference V̇O2 and V̇CO2 values in an in vitro simulation. The devices demonstrated good agreement with each other.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method.

BACKGROUND Volumetric capnography is an alternative method of measuring expired carbon dioxide partial pressure (P(eCO2)) and physiologic dead-space-to-tidal-volume ratio (V(D)/V(T)) during mechanical ventilation. In this method, P(eCO2) is measured at the Y-adapter of the ventilator circuit, thus eliminating the effects of compression volume contamination and the need to apply a correction fac...

متن کامل

Calculation of physiologic dead space: comparison of ventilator volumetric capnography to measurements by metabolic analyzer and volumetric CO2 monitor.

BACKGROUND Calculation of physiologic dead space (dead space divided by tidal volume [VD/VT]) using the Enghoff modification of the Bohr equation requires measurement of the partial pressure of mean expired CO2 (PĒCO2) by exhaled gas collection and analysis, use of a metabolic analyzer, or use of a volumetric CO2 monitor. The Dräger XL ventilator is equipped with integrated volumetric CO2 monit...

متن کامل

بررسی همبستگی و میزان توافق نتایج PaCO2 گازهای خون شریانی با CO2 انتهای بازدمی (End-Tidal CO2) توسط کاپنوگرافی در بیماران مبتلا به تشدید حاد بیماری انسدادی ریوی (COPD)

  Background : Chronic Obstructive Pulmonary Disease (COPD) represents a major public health problem. The course of COPD is characterized by episodic periods of worsening symptoms, termed exacerbations. Supplemental oxygen should be given to patients with COPD exacerbation without causing CO2 retention. Arterial blood gas sampling is the gold standard for monitoring adequate oxygenation and for...

متن کامل

Can Transcutaneous CO2 Tension Be Used to Calculate Ventilatory Dead Space? A Pilot Study

Dead space fraction (V d/V t) measurement performed using volumetric capnography requires arterial blood gas (ABG) sampling to estimate the partial pressure of carbon dioxide (PaCO2). In recent years, transcutaneous capnography (PtcCO2) has emerged as a noninvasive method of estimating PaCO2. We hypothesized that PtcCO2 can be used as a substitute for PaCO2 in the calculation of V d/V t. In thi...

متن کامل

End-tidal Carbon Dioxide Measurements in Unintentional Non-Fire-Related Carbon Monoxide Poisoning

Background: Poisoning with carbon monoxide occurs occasionally worldwide, and the gold diagnostic standard is to measure carboxyhemoglobin level in the blood. This study investigated the correlation between carboxyhemoglobin and the end-tidal carbon dioxide levels in 50 patients with carbon monoxide poisoning. Methods: We recruited 50 volunteer patients who had been admitted to the Emergency S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Respiratory care

دوره 61 3  شماره 

صفحات  -

تاریخ انتشار 2016