An illustration of an in-vivo corneal response to a soft lens presoaked in a non-isotonic solution.
نویسندگان
چکیده
The use of hydrophilic gel contact lenses as a carrier of a non-isotonic saline solution provokes an irreversible increase in corneal thickness in the in-vivo rabbit eye. Studies on humans confirm the nature of the animal response, and it is therefore suggested that particular care should be taken when patients prepare saline solutions.
منابع مشابه
مقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملبررسی تغییرات توپوگرافیک قرنیه بعد از اعمال جراحی اسکرال با کلینگ و ویترکتومی
To investigale the topographic changes in the cornea after scleral buckling and vitrectommy. A prospective study was conducted. Thses changes were analyzed based on the type of surgical procedures performed. Design of this study was observational prospective case series. 49 eyes from 48 patients were stratified into four groups based on the type of surgical procedures performed. 10 un...
متن کاملDendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study
BACKGROUND The purpose of this study was to assess whether differences in central corneal dendritic immune cell densities associated with combinations of soft contact lenses and lens care solutions could be detected by in vivo confocal microscopy. METHODS Participants were adults naïve to contact lens wear (n = 10) or who wore soft contact lenses habitually on a daily-wear schedule (n = 38) o...
متن کاملProduction and evaluation of [67Ga]-DTPA-Rituximab
Background: In order to obtain an anti-CD20 conjugate to be used in future therapeutic studies with therapeutic radioisotopes, 67Ga-labeled antibody was prepared as a model of metal chelated immunoconjugate for preliminary dosimetric and biodistribution studies. Materials and Methods: Rituximab was labeled with [67Ga]-gallium chloride after residulation with freshly prepared cyclic DTP...
متن کاملتخمین غیرتهاجمی مدول الاستیک چشم کاتاراکته شده خرگوش
Although cataract is very common and its detection seems apparently easy especially in the mature cataract, its quantitative description to determine the critical value of diagnosis is too difficult. Non-invasive evaluation of the mechanical properties of eye is hampered by the absence of in-vivo methods for direct assessment of the axial length of eye, lens and cornea. In the present study...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 62 1 شماره
صفحات -
تاریخ انتشار 1978