Rapid determination of amphotericin B levels in serum by high-performance liquid chromatography without interference by bilirubin.
نویسندگان
چکیده
A high-performance liquid chromatographic method for the determination of amphotericin B concentrations in human serum without bilirubin interference was developed and compared with a microbiological assay. The high-performance liquid chromatographic assay utilized a reversed-phase trimethyl silica column, simple sample preparation, and visible detection. Reproducibility studies yielded coefficient-of-variation ranges from 1.02 to 2.11% for within-day precision and 2.88 to 4.32% for between-day precision. The correlation coefficient with the microbiological assay was 0.984 for amphotericin B.
منابع مشابه
Interference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملSensitive high-pressure liquid chromatographic assay for amphotericin B which incorporates an internal standard.
We developed a rapid, sensitive, high-pressure liquid chromatographic (HPLC) procedure which incorporates a commercially available internal standard, 1-amino-4-nitronaphthalene, to measure amphotericin B in serum. Recovery was quantitative (greater than or equal to 90%), and the standard curve was linear from 0.04 to at least 10.0 micrograms/ml. The reproducibility of the assay was good, with i...
متن کاملInterference-free Determination of Carbamazepine in Human Serum Using High Performance Liquid Chromatography: A Comprehensive Research with Three-way Calibration Methods
In the present study, a comprehensive and systematic strategy was described to evaluate the performance of several three-way calibration methods on a bio-analytical problem. Parallel factor analysis (PARAFAC), alternating trilinear decomposition (ATLD), self-weighted alternating trilinear decomposition (SWATLD), alternating penalty trilinear decomposition (APTLD) and unfolded partial least squa...
متن کاملRapid colorimetric assay for acetaminophen without salicylate or phenylephrine interference.
A simple rapid, and economical procedure is presented for the quantitative determination of acetaminophen in serum. Acetaminophen is extracted into solvent, and, when back-extracted into base, is simultaneously reacted with Folin-Ciocalteau reagent to form a colored complex. The potential interference of bilirubin is eliminated by treatment with p-diazobenzene sulfonic acid. Results obtained wi...
متن کاملDetermination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography
Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Antimicrobial agents and chemotherapy
دوره 32 7 شماره
صفحات -
تاریخ انتشار 1988