EUROPEAN ORGANIZATION FOR NUCLEAR RESEARCH ORGANISATION EUROPEENNE POUR LA RECHERCHE NUCLEAIRE CERN MT/95-04 (DI) LHC Note 325 ASSEMBLY AND COMMISSIONING OF THE LHC TEST STRING P. Faugeras, for the LHC String Team

نویسنده

  • P. Faugeras
چکیده

The assembly of the first version of the LHC test string has now been completed and commissioned. It makes use of the prototype short straight section assembled at CERN with its quadrupole and of the first two 10 m long dipoles manufactured by industry. The LHC string will be used to study phenomena which can be observed only when the different components are assembled in a prototype LHC cell, and will be completed with two other dipole magnets, as soon as they become available. This paper describes the major components present in the LHC string and the issues related to its mechanical assembly. It also reports on the different stages of the commissioning of the cryogenic equipment, the powering and the quench protection systems, together with their associated industrial controls and the data acquisition system. Longer term evolution of the string configuration is finally described. Invited paper presented at the 1995 Particle Accelerator Conference Dallas, USA May 1-5, 1995

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

KSTAR Assembly and Vacuum Commissioning for the 1 st Plasma

The Korea Superconducting Tokamak Advanced Research (KSTAR) device site assembly was completed by May 2007. During the assembly period, several key technologies were developed to assemble the superconducting tokamak and its ancillary systems. As will be described in this paper, we encountered several problems and difficulties that mainly stemmed from the uniqueness of the superconducting tokama...

متن کامل

Status of design and construction of the Transition Radiation Tracker (TRT) for the ATLAS experiment at the LHC

The ATLAS Inner Detector consists of three sub-systems, the Pixel Detector at the innermost radius, the SemiConductor Tracker at intermediate radii, and the Transition Radiation Tracker (TRT) at the outermost radius in front of the electromagnetic calorimeter. The TRT provides a combination of continuous tracking with many projective measurements based on individual drift-tubes (or straws) and ...

متن کامل

Engineering within the Assembly, Verification and Integration (AIV) Process in ALMA

The Atacama Large Millimeter/submillimeter Array (ALMA) is a joint project between astronomical organizations in Europe, North America, and East Asia, in collaboration with the Republic of Chile. ALMA will consist of at least 54 twelve-meter antennas and 12 seven-meter antennas operating as an interferometer in the millimeter and sub-millimeter wavelength range. It will be located at an altitud...

متن کامل

Status of the Linac for the Italian Hadron-Therapy Centre CNAO

The Italian hadron-therapy centre CNAO (Centro Nazionale di Adroterapia Oncologica) [1] is designed for the treatment of tumours with proton and light ion beams and to clinical and radiobiological research. The design consists of two ECR ion sources, a 7 MeV/u injector linac identical to the linac of the Heidelberg ion therapy centre HIT [2][3] and a 400 MeV/u synchrotron. GSI delivers technica...

متن کامل

Overview of Recent Commissioning Results of KSTAR

KSTAR is an advanced tokamak with fully superconducting coils for the steady state plasma research. The detailed engineering design and infrastructure setup for R & D have been completed in 2001. In March 2008, after the construction period of seven years, the KSTAR assembly has been completed, by connecting the cryogenic transfer lines between the tokamak and the cryogenic distribution system....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995