Endovascular Edge-to-Edge Mitral Valve Repair

نویسنده

  • Thomas J. Fogarty
چکیده

Background—The edge-to-edge technique is an accepted method for the surgical repair of a regurgitant mitral valve. This study reports the initial use of an endovascular technology that enables a double-orifice edge-to-edge mitral valve repair without cardiopulmonary bypass in an animal model. Methods and Results—Adult pigs (n 14) were anesthetized, and left thoracotomy was performed for epicardial echo imaging. Using femoral vein access, a steerable guide catheter was placed transseptally into the left atrium. An implantable clip designed to grasp and approximate the middle scallops of the anterior and posterior mitral leaflets was introduced through the guide catheter. The clip was opened in the left atrium, advanced through the mitral orifice, and retracted to grasp the leaflet edges. When a functional double-orifice valve was confirmed by echo, the clip was closed to coapt the leaflets and detached from the delivery catheter. Before final clip detachment, echo demonstrated a double orifice in all 14 animals. In 2 studies, the clip released from the anterior mitral leaflet. Retrospective analysis of echo images indicated an incomplete grasp of the anterior leaflet. Immediate postmortem examination revealed that the clip successfully approximated the middle scallops of the anterior and posterior leaflets in all 12 double-orifice studies. Conclusions—This study demonstrates for the first time that an endovascular system can be successfully used to perform the edge-to-edge repair technique in a nondiseased porcine model. This technique is potentially applicable as a percutaneous catheterization laboratory procedure for the treatment of mitral regurgitation in humans. (Circulation. 2003;108:1990-1993.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous mitral valve repair: lessons from the EVEREST II (Endovascular Valve Edge-to-Edge REpair Study) and beyond.

The 24-month results of the EVEREST II (Endovascular Valve Edge-to-Edge REpair Study), presented at the American College of Cardiology 2011 Scientific Sessions/i2 Summit and recently published (1), investigating the safety and efficacy of the MitraClip (Abbott Vascular, Santa Clara, California) device, validated the interest in percutaneous approaches to the treatment of mitral regurgitation (M...

متن کامل

Percutaneous mitral valve repair for mitral regurgitation in high-risk patients: results of the EVEREST II study.

BACKGROUND The EVEREST II (Endovascular Valve Edge-to-Edge REpair STudy) High-Risk registry and REALISM Continued Access Study High-Risk Arm are prospective registries of patients who received the MitraClip device (Abbott Vascular, Santa Clara, California) for mitral regurgitation (MR) in the United States. OBJECTIVES The purpose of this study was to report 12-month outcomes in high-risk pati...

متن کامل

4-year results of a randomized controlled trial of percutaneous repair versus surgery for mitral regurgitation.

OBJECTIVES This study sought to evaluate 4-year outcomes of percutaneous repair versus surgery for mitral regurgitation. BACKGROUND Transcatheter therapies are being developed to treat valvular heart disease. In the EVEREST (Endovascular Valve Edge-to-Edge Repair Study) II trial, treatment of mitral valve regurgitation (MR) with a novel percutaneous device was compared with surgery and showed...

متن کامل

Finite element analysis for edge-to-edge technique to treat post-mitral valve repair systolic anterior motion.

Systolic anterior motion of the mitral valve is an uncommon complication of mitral valve repair, which requires immediate supplementary surgical action. Edge-to-edge suture is considered as an effective technique to treat post-mitral valve repair systolic anterior motion by clinical researchers. However, the fundamentals and quantitative analysis are vacant to validate the effectiveness of the ...

متن کامل

Surgical revision after percutaneous mitral valve repair by edge-to-edge device: when the strategy fails in the highest risk surgical population.

OBJECTIVES Percutaneous edge-to-edge devices for non-surgical repair of mitral valve regurgitation are under clinical evaluation in high-risk patients deemed not suitable for conventional surgery. To address guidelines for initial therapy decision, we here report on 13 cases of surgery after failed percutaneous edge-to-edge mitral valve repair or attempted repair, and discuss methodology and pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003