Assessment of Aortic Stenosis Severity Using Pressure Drop Coefficient: a Retrospective Study in Humans
نویسندگان
چکیده
1 ABSTRACT Accurate assessment of the stenosis severity is critical in patients with aortic stenosis (AS). The ambiguities and reduced sensitivities of the current diagnostic parameters can result in sub-optimal clinical decision making. In this preliminary study, we investigate the functional diagnostic parameter CDP (ratio of the transvalvular pressure drop to the proximal dynamic pressure) for the assessment of AS severity by correlating with the current diagnostic parameters. CDP was calculated using diagnostic parameters obtained from retrospective chart reviews. CDP values were calculated independently from Doppler and catheterization measurements. CDP exhibited better correlation with transvalvular pressure drop and jet velocity simultaneously, than when correlated independently with the same diagnostic parameters. CDP increases with increasing AS severity, which is consistent with hydrodynamic principles. This retrospective study is a prelude to a prospective study to evaluate CDP for AS severity assessment.
منابع مشابه
Non-invasive Assessment of the Severity of Aortic Stenosis by Doppler Derived Aortic Valve Coefficient: A Retrospective Feasibility Study in Humans
Background: Accurate assessment of the severity of stenosis is critical in patients with aortic stenosis. The ambiguities and imprecisions of the current diagnostic parameters can result in suboptimal clinical decisions. In this feasibility study, we investigate the functional diagnostic parameter AVC (Aortic Valve coefficient: ratio of the total transvalvular pressure drop to the proximal dyna...
متن کاملHemodynamic diagnostics of epicardial coronary stenoses: in-vitro experimental and computational study
BACKGROUND The severity of epicardial coronary stenosis can be assessed by invasive measurements of trans-stenotic pressure drop and flow. A pressure or flow sensor-tipped guidewire inserted across the coronary stenosis causes an overestimation in true trans-stenotic pressure drop and reduction in coronary flow. This may mask the true severity of coronary stenosis. In order to unmask the true s...
متن کاملInfluence of heart rate on fractional flow reserve, pressure drop coefficient, and lesion flow coefficient for epicardial coronary stenosis in a porcine model.
A limitation in the use of invasive coronary diagnostic indexes is that fluctuations in hemodynamic factors such as heart rate (HR), blood pressure, and contractility may alter resting or hyperemic flow measurements and may introduce uncertainties in the interpretation of these indexes. In this study, we focused on the effect of fluctuations in HR and area stenosis (AS) on diagnostic indexes. W...
متن کاملبررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی
Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...
متن کاملAssessment of severity of aortic stenosis through time-frequency analysis of murmur.
STUDY OBJECTIVE The accurate and inexpensive noninvasive assessment of the presence and severity of aortic stenosis remains a challenge. In this study, we performed spectral analysis on the murmurs of a group of patients with this disease in order to assess its severity. DESIGN An electronic stethoscope was used to generate a spectral analysis of murmurs in patients with aortic stenosis. The ...