Is Distal Femur Locking Plate a Superior Implant in Distal Femur Fracture?

نویسندگان

  • Anil Chander
  • Ganesan Ram Ganesan
  • Vignesh Jayabalan
چکیده

In spite of advances in techniques and improvements in surgical implants, confusion still prevails regarding use of specific implants in distal femur fracture. Fractures in the distal femur have posed considerable therapeutic challenges throughout the history of fracture treatment. Most of these surgical failures were due to inadequate fixation of the fracture fragments. The Aim of the study is to determine whether distal femur locking plates are superior implants than dynamic condylar screw and distal femur nail. A prospective and observational study was done in Department of Orthopaedics and Traumatology, Sri Ramachandra Medical Collage, Chennai between Jan. 2011 and Jan. 2015. Patients with distal femoral fractures, admitted into the hospital, were treated using various modes of internal fixation and followed up over a period of six months to one year and their functional outcome was evaluated. The functional and radiological assessment of patients during follow-up was done using Neer’s criteria. The use of any one of the implant, i.e. distal femur locking plates, dynamic condylar screw or distal femur nailing for internal fixation, depends on the type of fracture and the pre operative planning and intra operate decision of the surgeon. In our study, 38% of fractures treated by Dynamic condylar screw, 72% of fractures treated by distal femur locking plate and 42% of fractures treated by Distal femur supracondylar nail had excellent/satisfactory results. Locking plates had better outcome in both extra-articular and intra-articular group. They also had better outcome in both younger and older age groups.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stiffness of the locking compression plate as an external fixator for treating distal tibial fractures: a biomechanics study

BACKGROUND Locking compress plate, as external fixator, is an attractive technique for distal tibial fracture treatment. But it still remains unclear whether the external LCP has sufficient stiffness. Thus, the present study aims to make a comprehensive evaluation of the stiffness of external locking compress plate when it is used as an external fixator in distal tibial fractures treatment. M...

متن کامل

Functional Results of Unstable (Type 2) Distal Clavicle Fractures Treated with Superior Anterior Locking Plate

Background: The treatment of distal clavicle fracture is always a challenge, as it is mostly unstable and has higherrate of delayed union, malunion, non-union and associated acromioclavicular arthritis. So the management of thesefractures remains controversial. The purpose of this study is to evaluate the functional results of Type 2 distal endclavicle fractures treated with superior anterior l...

متن کامل

Reversed anatomic distal femur locking plate for periprosthetic hip fracture fixation.

The incidence of femoral fracture on hip prosthesis is increasing. Plate fixation is the method of choice when the prosthesis is stable. In fracture with proximal extension, the quality of the bone fixation is critical and, despite the development of anatomic plates, may be endangered when there are too few proximal screws. To resolve this issue, we recommend using a reversed LCP™ anatomic dist...

متن کامل

Reverse distal femoral locking compression plate a salvage option in nonunion of proximal femoral fractures

BACKGROUND When primary fixation of proximal femoral fractures with implants fails, revision osteosynthesis may be challenging. Tracts of previous implants and remaining insufficient bone stock in the proximal femur pose unique problems for the treatment. Intramedullary implants like proximal femoral nail (PFN) or surface implants like Dynamic Condylar Screw (DCS) are few of the described impla...

متن کامل

Finite element comparison of retrograde intramedullary nailing and locking plate fixation with/without an intramedullary allograft for distal femur fracture following total knee arthroplasty.

PURPOSE Periprosthetic distal femur fracture after total knee arthroplasty due to the stress-shielding phenomenon is a challenging problem. Retrograde intramedullary nail (RIMN) or locking plate (LP) fixation with/without a strut allograft has been clinically used via less invasive stabilization surgery (LISS) for the treatment of these periprosthetic fractures. However, their biomechanical dif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015